低温地板辐射采暖设计及其舒适性的试验研究-ijres.PDF

低温地板辐射采暖设计及其舒适性的试验研究-ijres.PDF

低温地板辐射采暖设计及其舒适性的试验研究-ijres

International Journal of Research in Engineering and Science (IJRES) ISSN (Online): 2320-9364, ISSN (Print): 2320-9356 Volume 4 Issue 1 ǁ January. 2016 ǁ PP.56-61 The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort 1 1 1 1 Sun Rui , Hang Xin , Liu Tuo Chen Yu (1.College of Mechanical Engineering, Shanghai University of Engineering Science, Shanghai 201620, China) Abstract: In order to analyze the temperature distribution of the low-temperature radiant floor heating system that uses the condensing wall-hung boiler as the heat source, the heating system is designed according to a typical house facing south in Shanghai. The experiments are carried out to study the effects of the supply water temperature on the thermal comfort of the system. Eventually, the supply water temperature that makes people in the room feel more comfortable is obtained. The result shows that in the condition of that the outside temperature is 8~15℃ and the relative humidity is 30~70%RH, the temperature distribution in the room is from high to low when the height is from bottom to top. The floor surface temperature is highest, but its uniformity is very poor. When the heating system reaches the steady state, the air temperature of the room is uniform. When the supply water temperature is 63℃ The room is relatively comfortable at the above experimental condition. Key words: low-temperature radiant floor heating system; condensing wall–hung boiler; temperature distribution; comfort I. Introduction Low-temperature radiant floor heating uses the low temperature water as the heat medium, and its heat coils are buried in the floor of building. It’s a

文档评论(0)

1亿VIP精品文档

相关文档