基于小波分析的配电系统故障定位研究-电力系统及其自动化专业论文.docxVIP

基于小波分析的配电系统故障定位研究-电力系统及其自动化专业论文.docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ABSTRACT As the explosive development of power industry and scale expansion of electric distribution network, particularly, the construction of the smart grid,people ask more stable power supplying. Line protection has entered a new automation era of using computer protection.As a efficient tool for mathematical analysis, wavelet has been used in power system widely . In this Article, wavelet is used in radial distribution network and tree distribution network. Faultpoints have more complex transient waves,what are generated with a large number of harmonics. Particularly,because of the compensation coming from power system with neutral grounding via arc suppression Coil, the zero-sequence information amplitude of fault traveling wave become small and could be smaller then system normal working.So it is difficult to obtain the characteristics of traveling wave generated from a faultpoint. In this Article, catch the first traveling wave of fault transient information by type c traveling wave distance measuring method and wavelet analysis, determine the traveling wave speed of the zero-mode wave when system working normally and measure the fault distance exactly.For the tree distribution network,insert a voltage traveling wave into system and record the zero-mode voltage wave of reflected traveling wave when system working normally,while insert a voltage traveling wave into the fault phase and record the zero-mode voltage wave of reflected traveling wave when system working abnormally,then subtract the two waveforms and eliminate the first reflection wave of network nodes and calculate the fault distance by wavelet analysis. Based on the completion of ranging, measure and analysis the voltage to earth of fault phase which is at the end of every line,the line which has the smallest voltage amplitude or the fastest changeing voltage amplitude is the fault line.The method is that:measure the fault distance and determine the point which is like the fault point,then select

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档