水内冷发电机空芯铜导线结垢物的表征和分析-失效分析与预防.pdf

水内冷发电机空芯铜导线结垢物的表征和分析-失效分析与预防.pdf

2006 8 August, 2006 1 3 Vo.l 1, No3 , (复旦大学材料科学系, 上海 200433) []; ; ; [] 300MW , , , ; [] TK262. 23+ 1 [] A [] 1673- 6214( 2006) 03-0038- 04 Analysis of Scaling Substance A dhered to H ollow Copp er ConductingW ire of In ternal CoolingW ater G enerator IU Yan-Li, YANG Zhen-Guo (D ep artment of Materials Science, Fudan University, Shanghai 200433, China) K ey w ord s: scaling substance; water cooling system; characterization; corrosion A bstrac t: To solve the phenomenon of abnormal temperature rising of generator stator slots of300MW unit, scaling substance adhered to the hollow copper conducting wire of generator statorwas characterized and analyzed by SEM, EDS and FT IR. The expermi ental re- sults showed that the scaling substancewere mainly polytetrafluoroethylene binding resin, fiberglass bundle, sealing germ and copper oxide from corrosion. The abnormal rising temperature of the stator slotswas due to scaling substance blocking hollow copper conducting w ire. 1 , , [ 1] , , , , , , , , [ 2] , CO O , pH , 2 2 2 O 2 ,,