Total Ionizing Dose
and Single-Event-Effects
Test Report
S-Series DC-DC Converter
Revision A
July, 2003
Executive Summary of S-Series Radiation Test Results
The S-Series converters were tested for TID (Total Ionizing Dose) and for Single Event Effects (SEE).
TID
A total of 5 devices each of different model types were tested at McClellan AFB near Sacramento California. Three of
the units tested were single output versions and two of the units were dual output versions. Of the single output models
the 3.3V, 5V and 15V output models were selected for testing. For the Dual versions, the 5V dual and 15V dual models
were selected for testing. All S-Series models of different output voltages are of similar circuit configuration.
Differences are magnetic turns ratios, output filtering component values, and compensation circuit values to
accommodate the specific output. The outputs of the units were loaded with a resistive load equal to ½ of the rated
maximum. The units were irradiated in a dose rate chamber containing 19,200 Curies of Co60. The chamber was set up
to provide a dose rate of approximately 1k rad (SiO2)/min. A screw driven automatic cart was used to position the units
relative to the source to obtain the desired dose rate. Tests were conducted in accordance with MIL-STD-883, Method
1019.5, condition B. After radiation exposure the parts were annealed at 100°C for 160 hours.
SEE
Single event testing was performed at Texas AM University in College Station, Texas. A total of three samples were
evaluated. The samples selected were the 3.3V single, 15V single, and 15V dual. The units were biased at full load
during irradiation. The parts were irradiated with xenon and gold ions producing LET levels of 47, 60 and 83 MeV⋅cm2 /
mg.
Conclusion
The S-Series parts passed the irradiation tests. Although not all the S-Series output voltages were tested, the results
should be considered applicable to the c
您可能关注的文档
- SW6-1998过程设备强度计算软件包用户手册.pdf
- XWu-SAE-C05-系统分析概述.pdf
- LED照明产品北美认证标准.pdf
- XDG号地块住宅商业及公建配套用房的全文公示环评公众参与环评报告.pdf
- Invariance principle for the marked coalescent point process:对于被标记的结合点过程不变性原理.pdf
- PKI技术及其在移动电子商务中的应用研究(上).pdf
- LTE系统小数据包业务无线资源优化研究.pdf
- 阿米巴经营体系导入与互动交流.pdf
- SUPER 304H 及HR3C 选用镍基焊材的焊接工艺及实际操作研究.pdf
- NOz和O3对PPS滤料老化影响研究.pdf
- P2P网贷出借人投资决策行为的影响因素及其监管要点——基于借款人信息的视角.pdf
- TD-LTE研究开发技术试验——终端设备测试方法(2.6GHz).pdf
- kV广丰三厂输变电工程电磁专章环评报告.pdf
- 阿露丝医疗美容门诊部环评报告.pdf
- YD∕T 1591-2009 移动通信终端电源适配器及充电∕数据接口技术要求和测试方法.pdf
- MW屋顶分布式光伏发电环评报告.pdf
- MARPOL7378各附则已生效,探讨我们还该干什么.pdf
- IC卡热量控制系统.pdf
- LED背光模怎的最新市场与技术趋势--光学膜片多北能整合技术(2010-10-29).pdf
- Inconel智能制造中心(一期)环评报告.pdf
文档评论(0)