* Star-Delta starters are very applicable to Low starting Torque devices such as compressor - motors. Limits inrush to 33% Long acceleration time Requires special 6 lead motor Lowest cost of reduced voltage * 4 Contactors: Start, Run, Short, Transition Transition Resistors Mechanical interlock between Run Shorting Contactors Timer control * * * Primary Reactor, connect reactor in the stator circuit, start with reactor and bypass the reactor when running. Auto-transformer, connect auto-transformer in the power circuit, start with part voltage and run in full voltage. * Low, 200 - 600 volts Medium, 601 - 69,000 volts High, 115,000 - 230,000 volts Extra High, 345,000 - 1,100,000 volts * * Power Circuits Controls incoming power to motor (on/off) Overload protective equipment Short circuit protection equipment Control Circuits Controls power components switching motor * * * * Do not confuse overload protection with short circuit protection! * * * Pressure transducer Application: Suction pressure for super heat control and low pressure protection Discharge pressure for high pressure protection Oil pressure for oil differential pressure protection Type: Variable capacitive Semiconductor piezoresistive Select by pressure range and output type (0~5V or 4~20ma) CH530 pressure transducer Working Pressure Range: 0 to 475 Psig Power: 24 +/- 10% VDC, 20mA max. Communications, RS485 Physical Layer, 19.2 Kbit CT/PT on CH530 Application CT (current transformer) detects 3 phase currents of compressor motor, for motor overload, phase reverse, phase loss, current imbalance protection PT (potential transformer) detects line voltage of power supply, for over / under voltage protection 3CTs and 3PTs connect to starter module can provide power meter function on CH530 control platform CT and PT can convert high current and voltage value to small value for control. We usually use CT with 50:0.1, 100:0.1, 150:0.1,200:0.1 …., PT with 600:30 Wiring must pay atten
您可能关注的文档
最近下载
- 浅谈初中物理教学语言严密性.doc VIP
- 高压配电柜日常维护保养方案.docx VIP
- 国考物理化学真题及答案.doc VIP
- 强制氧化-尿素还原法(FO-UR)烟气脱硝成套技术.doc VIP
- 2024年江苏赛区复赛“扬子石化杯”第38届中国化学奥林匹克(初赛)选拔赛暨化学试题含答案.pdf VIP
- 招标代理服务技术方案104页.docx
- 政府采购项目招标代理机构服务投标技术方案(技术标).pptx VIP
- 2025至2030中国建筑信息模型(BIM)行业发展趋势分析与未来投资战略咨询研究报告.docx
- 2024广东建设职业技术学院招聘笔试真题含答案详解.docx VIP
- 公司法中董事对第三人责任的性质界定与归责原则研究.docx VIP
文档评论(0)