- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
F – switch fuse disconnector Back to SafePlus modules Switch fuse combination Three phase fuse tripping Mechanism pre-charged for tripping Up and downstream dual earthing switch No jammed fuse covers - open by handle Fuse tripping in front - real blown fuse indicator Fully submersible - unique for switch fuse 400 series cable bushings available V – vacuum circuit breaker Back to SafePlus modules 630A or 200A vacuum circuit breaker Latched mechanism – close and open coil Separate isolator/earthing switch Protection as specified by our customers Tripping facilitated for a wide range of relays Combisensor available CB – VD4 circuit breaker Back to SafePlus modules 630A or 1250A VD4 vacuum circuit breaker Interlocked disconnector/earthing switch Current and voltage sensor techniques REF control and protection unit Motor operated circuit breaker and disconnector/earthing switch Sl – busbar sectionaliser Back to SafePlus modules Three position load break switch Interlocked earthing switch Manual or motor operation Only 325mm wide when placed between other modules Sv – with vacuum circuit breaker Back to SafePlus modules 630A vacuum circuit breaker Separate isolator/earthing switch D – direct cable connection Back to SafePlus modules Direct cable connection De – with earting switch Back to SafePlus modules Direct cable connection Earthing switch with making capacity Be – busbar earthing Back to SafePlus modules Busbar earthing Earthing switch with making capacity M - Metering Back to SafePlus modules Air insulated and factory assembled module Type tested with specific transformers 2 or 3 pcs DIN 42600 Narrow type CT’s with ribs. 3 pcs. DIN 42600 Narrow type single pole VT’s Fuses on VT primary (optional) 400series bushings for busbar connection Bottom cable entry available Switchgear Design (C) Three position switch Switch, disconnector, earth Arc quenching by SF6 gas Rough and reliable with a minimum of parts Switchgear Des
文档评论(0)