Impinj_Reader 如何进行健康度管理.pdfVIP

  • 18
  • 0
  • 约2.25万字
  • 约 8页
  • 2020-05-22 发布于北京
  • 举报
  Application Note READER HOW-TO HEALTH MONITORING Version 1.00 © 2019, Impinj, Inc. This document provides a description of how to monitor the health of an Impinj Speeday® RAIN RFID reader. TABLE OF CONTENTS Introduction 2  Keep Alives 2  Minimizing the impact of network connectivity on tag reads 3  Reader Events 3  SNMP Traps 4  Detecting SNMP Traps in Code 5  Glossary Error! Bookmark not defined.  Notices 7  INTRODUCTION ® The following document describes how to use the built-in features of Impinj Speedway RAIN RFID readers to detect various failures, including those related to network, antenna connectivity issues and internal software. Hardware failures of the Speedway readers are rare, but can still affect the performance of an RFID system. When a hardware failure occurs, Speedway can use Low Level Reader Protocol (LLRP) communications to recover automatically, if LLRP communications are configured to detect failures and re- establish connectivity. This document covers implementation details and applicable .NET C# code examples to show how to configure a failure detection feature with the Impinj Octane™ Software Development Kit (SDK). The examples used are based on the 2.32.1 release of Octane SDK. KEEP ALIVES (READER-CLIENT HEARTBEAT) Speedway readers support the LLRP Keep Alive mechanism. LLRP Keep Alive provides a ‘heartbeat’ communication between the reader and client applications via KEEPALIVE and KEEPALIVE_ACK messages. The reader sends periodic KE