READ ME FIRST
Known Issues:
Data Domain SRS connect home stops working after a DD OS upgrade to 6.1.x, 6.2.x, or 7.1.x.
This happens to Data Domain systems with connectemc configured as the support notification method.
Please refer to KB 79715 for more information. An upgrade to DD OS 7.3.x.x does not have this problem.
Upgrade from DD OS 6.1.x [or] 6.2.x
I. Introduction:
Using Minimal Disruptive Upgrade (MDU), customers can now easily upgrade from DDOS 6.1.x [or]
DDOS 6.2.x to DDOS 7.2.0.50-671975.
It is highly recommended to use MDU for a smooth upgrade process.
II. Packages:
A. The customer must use mdu-upgrade-bundle-6.1-releases.rpm to successfully complete DDOS
6.1.x to DDOS 7.2.0.50 upgrade
B. The customer must use mdu-upgrade-bundle-6.2-releases.rpm to successfully complete DDOS
6.2.x to DDOS 7.2.0.50 upgrade
Single node/DDVE upgrade path is summarized as below:
a) DDOS 6.1.x -- mdu-upgrade-bundle-6.1-releases.rpm -- DDOS 7.2.0.50
b) DDOS 6.2.x -- mdu-upgrade-bundle-6.2-releases.rpm -- DDOS 7.2.0.50
HA node upgrade path is summarized as below:
a) DDOS 6.1.x (Active HA node) -- mdu-upgrade-bundle-6.1-releases.rpm -- DDOS 6.1.2.70 --
DDOS 7.2.0.50
Note: HA that is running 6.1.2.70 and above don’t need to apply the MDU and can upgrade
directly to DDOS 7.2.0.50
b) DDOS 6.2.x (Active HA node) -- mdu-upgrade-bundle-6.2-releases.rpm -- DDOS 7.2.0.50
III. MDU DDOS upgrade procedure can be performed either by:
(Please read SYSTEM as Source DDR [or] DDVE [or] Act