;;MACS TL Components;Approach;T5-T 10 Mini TTA Rib / Lung Blade
= Retraction balloon
T11 - L2 Mini TTA
Rib / Diaphragm Blade
= Fixation Pin for Diaphragm Blade
L2-L5 Mini-ALIF
Retroperitoneal
L5- S1 Mini ALIF
Transperitoneal (Mini TTA Frame);Set Configuration
Mini TTA Retractor (BV 148)
(Same Retractor as Miaspas mini-ALIF)
;Disposables
1x BV 182 P Pump for retraction ballon
1x BV 184 P Retraction ballon, Size ?S“
1x BV 185 P Retraction ballon, Size ?M“
1x BV 186 P Retraction ballon, Size ?L“
1x BV 173 S Fixation Pin for Diaphragm Blade, Size ?S“
1x BV 174 S Fixation Pin for Diaphragm Blade, Size ?M“
1x BV 175 S Fixation Pin for Diaphragm Blade, Size ?L“;Approach Microsurgical - Mini TTA;;;;;MACS TL Components;MACS TL Components;Fractures T8 - L3
AO-classification (Magerl)
A-fractures with loss of anterior vertebral body height 50%
A 2.3, A 3
B and C fractures with posterior instrumentation
Stenosis
Tumors
Deformities;M, 24Y
A3.1
L 12
;Post-Op;;MACS TL Strengths;AESTHETICS - Form and function
Low profile compact design
Round edges
Color coded implants
;Dr. Beisse / Dr. Potulski / Prof. Bühren
BGU Murnau, Germany
Dr. Mayer
München - Harlaching, Germany
Prof. Kinzl
University of Ulm, Germany
Dr. Marnay
Montpellier, France;Instruments
Preparation FW 346
Insertion FW 344
ATTENTION:
Specific instruments have to
be ordered separately;Step 1
Assembly of K-wire insertion instrument;Step 2
Reaming of Cortex;Step 3
Preassembly of Polyaxial Screw / Centraliser;Step 4
Connection of Insertion Instr.;MACS TL Operation Technique;MACS TL Operation Technique;Step 5
Screw Insertion;Step 6
K-Wire Removal;Step 7
Disconnection of Insertion Device.;Step 8
Distraction;Step 9
Measuring / Plate Positioning.;Step 10a
Nut Placement;Step 10b
Nut Tightening;Step 11
Centralizer Removal;Step 12
Assembly in Final Position /
Screw Insertion;Step 13a
Attachement of Targeting Instrument;Step 13b
Insertion of Stabilisation Screw;Step 13c
Removal of Targeting Instrument;St