4115GPECSequenceofOperationDatabaseGuide:4115格菱动力操作序列数据库指南.docVIP

4115GPECSequenceofOperationDatabaseGuide:4115格菱动力操作序列数据库指南.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
4115GPECSequenceofOperationDatabaseGuide:4115格菱动力操作序列数据库指南.doc

Application (Field Installed) GPEC Sequence of Operation Database Misc. Sequence of Operations Note: The following is a sample of a typical sequence of operations that may be adapted for a particular project. This is provided as a suggestion on how to write a sequence of operation for a specific project. The GPEC controller includes the ability for the operator to select some different sequences. Consult your Carrier representative if the sample sequence requires alterations. SEQUENCE OF OPERATION DATABASE AC1 AIR COMPRESSOR PRESSURE A pressure transmitter located in the control air main will indicate air compressor pressure. If air pressure drops below 40 psi or rises above 95 psi an alarm will be generated. C1 Cooling Coil w/ Mix Damper OA Enthalpy Mixed air dampers and cooling coil valve are modulated in sequence to maintain a desired discharge temperature. When outside air enthalpy is greater than return air enthalpy, the mixed air dampers will be driven to their minimum positions. When outside air enthalpy is less than return air enthalpy, mixing dampers and cooling coil valves will modulate in sequence to maintain the desired space temperature. C2 Cooling Coil w/ Mix Damper SPT Enthalpy Mixed dampers and cooling coil valve are modulated in sequence to maintain a desired space temperature. When outside air enthalpy is greater than return air enthalpy, the mixing dampers will be driven to their minimum position. When outside air enthalpy is less than space air enthalpy, mixing dampers will modulate to provide free cooling. Space air sensor will modulate the cooling coil valve to maintain a desired temperature. C3 Cooling Coil Control of SPT w/ RH Cooling coil valve is modulated to maintain a desired space temperature. Space air sensor will modulate cooling coil valve to maintain a desired temperature. If return air humidity rises above user setpoints, cooling coil valve will be modulated to maintain a lower setpoint. C4 Cooling Coil Control of SPT Cooling coil

文档评论(0)

docindoc + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档