RAID工作原理图解及特点分析.doc
RAID 0: Striped Disk Array without Fault Tolerance
Characteristics/Advantages
1. RAID 0 implements a striped disk array, the data is broken down into blocks and each block is written to a separate disk drive
2. I/O performance is greatly improved by spreading the I/O load across many channels and drives
3. Best performance is achieved when data is striped across multiple controllers with only one drive per controller
4. No parity calculation overhead is involved
5. Very simple design
6. Easy to implement
Disadvantages
1. Not a “True” RAID because it is NOT fault-tolerant
2. The failure of just one drive will result in all data in an array being lost
3. Should never be used in mission critical environments
Recommended Applications
1. Video Production and Editing
2. Image Editing
3. Pre-Press Applications
4. Any application requiring high bandwidth
RAID Level 0 requires a minimum of 2 drives to implement
RAID1: Mirroring and Duplexing
Characteristics/Advantages
1. One Write or two Reads possible per mirrored pair
2. Twice the Read transaction rate of single disks, same Write transaction rate as single disks
3. 100% redundancy of data means no rebuild is necessary in case of a disk failure, just a copy to the replacement disk
4. Transfer rate per block is equal to that of a single disk
5. Under certain circumstances, RAID 1 can sustain multiple simultaneous drive failures
6. Simplest RAID storage subsystem design
Disadvantages
1. Highest disk overhead of all RAID types (100%) - inefficient
2. Typically the RAID function is done by system software, loading the CPU/Server and possibly degrading throughput at high activity levels. Hardware implementation is strongly recommended
3. May not support hot swap of failed disk when implemented in “software”
Recommended Applications
1. Accounting
2. Payroll
3. Financial
4. Any application requiring very high availability
For Highest performance, the controller must be able to perform two concurrent separate Reads per mirrored pai
您可能关注的文档
- EAP框架下高校图书馆学科馆员压力管理的研究.doc
- ebrwlpy医学_文献检索试题.doc
- EDA课程实训设计(交通信号灯设计实现).doc
- EDP系列装置软件平台培训资料.doc
- Edyhos医学文献检索试题.doc
- EF基于制度理论视角的我国社会体育制度研究.doc
- EJB调用原理分析.doc
- Eqpsra中国外语教育研究中心中小学英语教育研究中心议案.doc
- ERDASIMAGINE图像预处理.ppt
- ERP企业在中国发展现状及措施分析.doc
- DB44_T 2611-2025 城市排水管网有毒有害气体监测与风险分级管理技术标准.pdf
- DB44_T 2612-2025 竞赛类科普活动策划与实施服务规范.pdf
- DB43_T 2947-2024 烟草种子质量控制规程.pdf
- DB37_T 4836-2025 煤矿风量实时监测技术要求.pdf
- 叉车防撞系统,全球前22强生产商排名及市场份额(by QYResearch).docx
- 超滤膜,全球前18强生产商排名及市场份额(by QYResearch).docx
- DB62T 4172-2020 玉米品种 酒623规范.pdf
- DB62T 4160-2020 在用真空绝热深冷压力容器综合性能在线检测方法.pdf
- DB62T 4164-2020 辣椒品种 酒椒1号.pdf
- DB62T 4133-2020 公路隧道地质超前预报机械能无损探测技术规程.pdf
文档评论(0)