并联型有源电力滤波器电流控制的等效原理.pdfVIP

  • 10
  • 0
  • 约3.94万字
  • 约 6页
  • 2016-03-10 发布于湖北
  • 举报

并联型有源电力滤波器电流控制的等效原理.pdf

并联型有源电力滤波器电流控制的等效原理.pdf

26 卷 15 期 中 国 电 机 工 程 学 报 Vol.26 No.15 Aug. 2006 2006 年8 月 Proceedings of the CSEE 2006 Chin.Soc.for Elec.Eng. 文章编号:0258-8013 (2006) 15-0040-06 中图分类号:TM921; TM714 文献标识码:A 学科分类号:47040 并联型有源电力滤波器电流控制的等效原理 王广柱 (山东大学电气工程学院,山东省济南市250061 ) Equivalence Principle of Current Control for Shunt Active Power Filters WANG Guang-zhu (Electrical Engineering School, Shandong University, Jinan 250061, Shandong Province, China) ABSTRACT: Two main types of schemes are used in shunt 关键词 电力电子;有源电力滤波器;等效原理;电流控制; Active Power Filters (APF) control: the conventional control 谐波及无功电流 scheme which is based on detecting and calculating the harmonic and reactive currents of nonlinear loads, and the 0 引言 direct ac main current control scheme which does not require 1976 年,Gyugyi 等人提出了采用 PWM(pulse the harmonic and reactive currents to be sensed and computed. This paper analyzes and demonstrates the inherent relations width modulation)控制变流器构成的有源电力滤波 between the two types of control schemes and concludes that 器(active power filter, APF)[1],确立了APF 的完整概 they are equivalent for current control. A new control scheme 念和主电路拓扑结构。特别是20 世纪80 年代以来, based on this conclusion is proposed and discussed, and the 由于新型电力半导体器件的出现,以及日本学者赤 harmonic and reactive currents signal calculated in a 木泰文(H. Akagi) 的基于瞬时无功功率理论的谐波 conventional APF is found to behave as j ust a feed-forward [2] 瞬时检测方法的提出 ,APF 得以迅速发展。至今

您可能关注的文档