PDOC-476-CTRU-06 Rotating equipment installation procedure

Client PETRODAR OPERATING COMPANY LIMITED PMC: Contractor CHINA PETROLEUM ENGINEERING CONSTRUCTION CORPORATION DOCUMENT No.: PDOC/476-CTRU-06 CONTRACT No: PDOC/23/06-476 GUMRY Field Production Facilities Project ROTATING EQUIPMENT INSTALLATION PROCEDURE REVISION RECORD Rev. NO. Submission Date Revision Details Prepared By Approved By OWNER A 2007-9-23 Submitted for reviewed Li Yonggang CONTENTS Scope Reference Documents General Rotating equipment installation Pumps Packaged Compressors Installation of Crane Quality record and review reports Revision note 1.0 Scope To define and establish procedures for on site handling, movement and installation of mechanically rotating equipment. Reference Documents Approved for Construction Engineering Drawings Piping Instrument Drawings PID Piping Arrangement Drawings Isometric Drawings Piping Support Pilling Layout Drawings API Std 610 Seventh Edition, February 1989-Centrifugal Pumps for General Refinery Services API Std 674 Maximum Allowable Speed Rating for Power Pumps in Continuous Services API RP 521 Guide for Pressure Relieving and Depressuring System Project Standards, Codes Specifications PDOC-SP-MEC-039 Specification for Multiphase Pumps PDOC-SP-PIP-002 Specification for Piping Design and Layout PDOC-SP-CIV-011 Specification for Piling Installation Project Quality Plan Vendor Installation Manuals Materials Handling Procedure 3.0 General 3.1 Foundations shall be completed and checked for correctness and levelness as per drawings and specifications. Prior to installation, foundation shall be clean with correct anchor boltholes location, centerlines marked, elevations and levels established for correctness. Shimming and wedging shall be carried out as per drawings and specifications. 3.2 As required, perform on-site installation of the various equipments as per approved construction drawings and specifications, and instruction by a manufacturer/vendor representative. 3.3 Final insulation jacketing

文档评论(0)

cj80011 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档