低压配电系统用涌保护器符合性认定检测细则
通信局(站)低压配电系统用电涌
保护器检验实施细则
目 录
1 编制依据及适用范围 ···························································································· 1
2 引用标准 ·················································································································· 1
3 检验项目及技术要求····························································································· 1
3.1 检验项目及技术要求····················································································· 1
3.2 对各种类型SPD 检测项目········································································· 7
4 检验方法·················································································································· 9
5 抽样 ························································································································· 9
5.1 抽样基数········································································································· 9
5.2 样品数量········································································································· 9
6 质量判定 ················································································································· 9
6.1 通信局(站)低压配电系统用电涌保护器监督总体的检验项目和质量判定 ····················································································································· 9
6.2 判定准则·········································································································· 9
通信局(站)低压配电系统用电涌保护器检验实施细则
1 编制依据及适用范围
本实施细则依据YD/T1235.1-2002《通信局(站)低压配电系统用电涌保护器技术要求》编制。
本细则适用于通信局(站)低压配电系统用电涌保护器的质量检验。
2 引用标准
GB/T4942-1993 低压电器外壳防护等级(eqv IEC60947:1988) YD/T1235.2-2002 通信局(站)低压配电系统用电涌保护器测试方法 3 检验项目及技术要求
3.1 检验项目及技术要求(见表1至表10)
表1检验项目及技术要求
序号 项目名称 技术要求 1 外观质量 a)电涌保护器表面应平整、光洁、无划伤、无裂痕及变形,紧固件应牢固,颜色应均匀无明显差异。
b)标志应完整清晰、耐久可靠,内容完全,且铭牌不应出现移动和任何翘曲现象。 2 保护模式 交流SPD必须具备N-PE、L-PE或L-N-PE的保护模式;直流SPD必须具备V+-V-的保护模式。
交流SPD宜具备L-N的保护模式;
直流SPD宜具备V+-PE或V--PE的保护模式。 3 分离装置 SPD在故障或