ppt课件-module2thehealthcarewastemanagementsystem.pptVIP

ppt课件-module2thehealthcarewastemanagementsystem.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ppt课件-module2thehealthcarewastemanagementsystem

Source: Hospital Incinerator Operator Training Course, USEPA, 1989 * Source: Hospital Incinerator Operator Training Course, USEPA, 1989 * * * Maintenance of Air Pollution Control Example of a baghouse filter maintenance schedule Daily: check stack, pressures, compressed air, damper valves, dust removal system, subsystem operations Weekly: check filter bags, hoppers, and cleaning system Monthly: check shaker mechanism, monitors Quarterly: inspect inlet plenum, gaskets, shaker mechanism Semi-annually: lubricate all motors and fans Annually: check bolts and welds, inspect whole system Troubleshooting Incinerators Symptom: Black smoke from the stack Possible Causes: Incomplete burning of waste, not enough air, overcharging of waste or volatile material, poor mixing in the secondary chamber, burner failure, primary chamber temperature too high Possible Solutions: Increase secondary chamber air, decrease underfire or overfire air, ensure secondary chamber temperature is above the minimum, decrease charge rate, check burners, install or check air pollution control system Troubleshooting Incinerators Symptom: Steady white or blue-white smoke from stack Possible Causes: Aerosols in the stack gas, too much air entering the incinerator, secondary chamber temperature is too low Possible Solutions: Check secondary chamber burner, ensure that secondary chamber temperature is above 1000oC, decrease underfire air, decrease secondary chamber air, check if waste contains pigments or metallic oxides, install or check air pollution control system Troubleshooting Incinerators Symptom: White smoke or white haze appears a short distance from the stack Possible Causes: Condensation of hydrochloric acid Possible Solutions: Reduce amounts of chlorinated materials in the waste, eliminate chlorinated plastics in the hospital, install a scrubber or check the efficiency of the gas scrubber Troubleshooting Incinerators Symptom: Smoke coming out of the primary chamber Possible Causes: Positive pr

文档评论(0)

bgl001 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档