g e n e r i c s p e c i f i c a t i o n f o r h i g h p e r f o r m a n c e r e v e n u e p o w e r(g e n e r c s p e c我f f i c t i o n o r h i g h p e r f o r m e n c r e v e n u e p o w e r).docVIP

g e n e r i c s p e c i f i c a t i o n f o r h i g h p e r f o r m a n c e r e v e n u e p o w e r(g e n e r c s p e c我f f i c t i o n o r h i g h p e r f o r m e n c r e v e n u e p o w e r).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Generic Specification For Transient Recorder and Power Meter with Advanced Power Quality and Communication Nexus? 1500 Meter 2. PRODUCT 2.1 Power Meter The meter shall be UL listed and CE marked. The meter shall be designed for multifunction electrical measurement on 3 phase power systems. The meter shall support 3-element Wye, 2.5 element Wye, 2 element Delta, and 4-wire Delta systems. The meter’s surge withstand shall conform to IEEE C37.90.1 and ANSI C62.41 (6kV). The meter shall be user programmable for voltage range to any CT or PT ratio. The meter shall have a voltage burden of not more than 0.072VA per phase Max at 600V, and 0.003VA per phase Max at 120 Volts. The meter shall have a current inputs burden of not more than 0.008VA per phase Max at 20 Amps. The meter shall accept a voltage input range of (5 to 347) VAC Line to Neutral, and a range of (10 to 600)VAC Line to Line. The meter shall accept a current reading of up to 20 Amps continuous. Start-up current for a 5 Amp input shall be no greater than 0.005 Amps. The meter shall have a frequency range of (45 to 69.9)Hz. The power meter shall use a dual input method for current inputs. Method one shall allow the CT to pass directly through the meter without any physical termination on the meter, ensuring the meter cannot be a point of failure on the CT circuit. The second method shall provide additional termination pass-through bars that allow the CT leads to be terminated on the meter. The Fault Current Withstand shall be 100 Amps for 10 seconds, 300 Amps for 3 seconds, and 500 Amps for 1 second at 23o C. The Pass-through wire gauge dimension of 0.177” / 4.5 mm shall be available. All inputs and outputs shall be isolated to 2500 Volts AC. The power meter shall measure and report the following quantities at a minimum: Watts (total and per phase), VARs (total and per phase), VA (total and per phase), Power Factor (total and per phase), voltage max/min in the Interval, and Fre

您可能关注的文档

文档评论(0)

heti94575 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档