The Armamentarium Indiana University South Bend医疗设备印第安那大学南本德.pptVIP

The Armamentarium Indiana University South Bend医疗设备印第安那大学南本德.ppt

  1. 1、本文档共26页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
The Armamentarium Indiana University South Bend医疗设备印第安那大学南本德

The Armamentarium 4 PARTS: 1) The Syringe 2) The Needle 3) The Cartridge 4) Preparation The Syringe Standard of Care ? aspirating dental syringes are the standard of care due to their ability to aspirate blood if the tip of the needle is located intravascularly ADA Standards for Injection Syringes They must be durable and able to withstand repeated sterilization without damage 2. They should be capable of accepting a wide variety of cartridges and needles from different manufacturers and permit repeated use 3. They should be inexpensive, self-contained, lightweight and simple to use with one hand 4. Provide aspiration so blood can be seen through the glass cartridge Breech-Loading, Metallic, Cartridge-Type, Aspirating #1 Used Syringe In Dentistry -breech loading implies that the dental cartridge is loaded from the side -a needle is attached to the barrel of the syringe at the needle adaptor -the needle passes into the barrel and pierces the diaphragm of the local anesthetic cartridge Aspirating Syringe -the needle adaptor is sometimes inadvertently discarded along with the disposable needle -the harpoon is a sharp tip attached to the piston and is responsible for penetrating the thick silicone rubber stopper (bung) at the other end of the cartridge - negative pressure is applied to the thumb ring by the administrator, if blood enters the glass local anesthetic cartridge (carpule) then the tip of the needle is inserted into the lumen of a blood vessel chrome-plated brass and stainless steel -incidence of positive aspiration is between 10-15% for some injections -aspiration before injection of local anesthetic is accepted in the practice of dentistry and is overlooked to a great extent -these syringes use the elasticity of the rubber diaphragm in the anesthetic cartridge to obtain the necessary negative pressure for aspiration -multiple aspirations are possible with very little effort due

文档评论(0)

118books + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档