8--Comparison of Losses and Efficiency in Alternate
ΦAbstract -- The performance of the optimized conventional,
novel E- and C-core flux-switching permanent magnet (FSPM)
machines having different combination of stator and rotor pole
numbers is compared by finite element analyses, with
particular reference to the conductor and magnet eddy current
loss and iron loss. Both iron loss and conductor eddy current
loss increase with the rotor pole number, while the 11- and 13-
rotor pole machine always exhibit lower magnet eddy current
loss than those of the 10- and 14-rotor pole machine,
respectively. The E- and C-core machines use half number and
volume of magnets but exhibit higher efficiency than those of
the conventional FSPM machine.
Index Terms-- Brushless, direct drive, flux-switching,
permanent magnet, torque density.
I. INTRODUCTION
S a kind of permanent magnet (PM) brushless AC
machine with non-overlapping windings, a flux-
switching PM (FSPM) machine [1-3] exhibits high
torque density and efficiency which are similar to those of a
fractional-slot PM machine [4]. Hence, it has been
extensively investigated recently [5-9]. The design
parameters of the FSPM machine were optimized and its
electromagnetic performance was analyzed in [4], [10]. The
other design considerations, such as the influence of end-
effect [11], iron loss [12], [13], eddy current loss in magnets
[14], proximity copper loss [15], [16], were investigated.
On the other hand, new topologies of FSPM machine
were proposed. In [2], the 3-phase FSPM machine was
developed from the 1-phase FSPM machine which was
firstly introduced in 1950s [1]. Then the alternate pole
wound and multi-phase FSPM machines were investigated
in [17], [18]. However, the foregoing machines have large
magnet usage which also reduces the slot area since the
magnet is on the stator, Figs. 1(a) and (b). In order to reduce
the magnet usage, the stator pole without armature winding
in the conventional FSPM machine with alternate poles
wound, Fig
您可能关注的文档
- 2015-TiO2LDH--光催化产氧--Advanced_Functional_Materials.pdf
- 2015人大经济思想史考博历年真题参考书复习策略-育明考博分校.pdf
- 2015乐加乐英语六年级英超A班选拔考试样卷.pdf
- 2015大学英语竞赛B类初赛答案.FIT).pdf
- 2015年10月11日大陆托福考试口语真题回顾(范文版)-智课教育旗下智课教育.pdf
- 2015年11月8日大陆托福考试口语真题回顾-智课教育旗下智课教育.pdf
- 2015年12月12日托福写作机经预测.pdf
- 2015年1月31日-2月1日托福口语预测.pdf
- 2015年6月28日GRE数学真题大回顾-智课教育旗下智课教育.pdf
- 2015年7月五期,“萌妖”胡巴来袭.pdf
- 8-1线性变换及其运算-1.pdf
- 8. 永磁式双凸极电机新型调速系统.pdf
- 532 of very high spatial resolution satellite image Comparison segmentations.pdf
- 800H-AB参数表.pdf
- 8Bunit4 集体备课.doc
- 912 Gene discovery in Carcinus maenas and Homarus americanus via expressed sequence tags.pdf
- 90-degree domain wall relaxation and frequency dependence of the coercive field in the ferr.pdf
- 8A_unit7_reading.ppt
- 92年4月gre考试阅读真题解析(B)-智课教育旗下智课教育.pdf
- 93年10月gre考试阅读真题解析(B)-智课教育旗下智课教育.pdf
文档评论(0)