- 1、本文档共13页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Multi-slice spiral CT angiography in aortic dissection Application
PAGE \* MERGEFORMAT 13
Multi-slice spiral CT angiography in aortic dissection Application
Rollins, ZHU Yong-hua, the mother-Qing Jin, Wang Shuqing
[Abstract] Objective To investigate the multi-slice spiral CT angiography (MSCTA) in the diagnosis of aortic dissection and clinical treatment of the application. Methods 15 cases of dissecting aneurysm were carried out multi-slice CT (MSCT) and enhanced thoraco-abdominal plain and raw data in the SGI workstations, multi-planar reconstruction (MPR), shaded surface display (SSD), maximum intensity projection (MIP ) and the volume of processing (VR) and other post-processing. Results 15 cases were a good demonstration of the entire aorta and its branches, true cavity, false lumen, intimal flap, and dissection of the location, extent satisfactory display. Conclusion MSCTA diagnosis of dissecting aneurysm of accurate, quick and effective method of choice for examination, with a high clinical value.
[Keywords:] Aneurysm, dissecting; tomography, spiral computed; Angiography
The utilization of multislice spiral CT angiography in aneurysm of aorta
LUO Lin, ZHU Yong hua, MU Qing jin.et al.CT Room, Department of Radiology, The First People’s Hospital, Qujing 655000, China
[Abstract] Objective To investigate the value of multislice spiral CT angiography (MSCTA) for the diagonosis and treatment of disseting aneutysm of aorta.Methods MSCT for chest and belly scanning and enhanced scanning was performed in 15 patients and the data was transferred to SGI workstation for image post processing including MPR, SSD, MIP and VR (4D Angio). Results The whole aorta and branches in 15 patients were displayed well by MSCTA.The true lumen, false lumen, intimal flap, location and extend of dissecting aneurysm were showed in all psatients satisfactorily.Conclusion MSCTA is accurate, fast and effective for the diagnosis of dissecting aneutysm.
[Keywords:] aneurysm, dissecting; tomography, spiral computer; angio
您可能关注的文档
- Movie Marketing- Far beyond the implant.doc
- Moved to the plateau of color Doppler ultrasound system of young male right heart changes in the parameters.doc
- Movies also need to locate.doc
- Moving film about the anti-cancer with chemotherapy in advanced colorectal cancer clinical observation.doc
- Movie Marketing implanted four principles.doc
- Moxa burning room air disinfection diseases and Kaoru.doc
- Moxa cone moxibustion Clinical efficacy of treatment of herpes zoster.doc
- Moving film about the anti-cancer with chemotherapy in advanced colorectal cancer clinical observation_0.doc
- Moxibustion head points based on cerebrospinal fluid of patients with vascular dementia of somatostatin and arginine vasopressin levels of the randomized controlled trials.doc
- Moxibustion Guanyuan chemotherapy in the treatment of advanced lung cancer patients and nursing observation of bone marrow suppression.doc
文档评论(0)