网站大量收购独家精品文档,联系QQ:2885784924

Multi-slice spiral CT angiography in aortic dissection Application.doc

Multi-slice spiral CT angiography in aortic dissection Application.doc

  1. 1、本文档共13页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Multi-slice spiral CT angiography in aortic dissection Application

 PAGE \* MERGEFORMAT 13 Multi-slice spiral CT angiography in aortic dissection Application Rollins, ZHU Yong-hua, the mother-Qing Jin, Wang Shuqing [Abstract] Objective To investigate the multi-slice spiral CT angiography (MSCTA) in the diagnosis of aortic dissection and clinical treatment of the application. Methods 15 cases of dissecting aneurysm were carried out multi-slice CT (MSCT) and enhanced thoraco-abdominal plain and raw data in the SGI workstations, multi-planar reconstruction (MPR), shaded surface display (SSD), maximum intensity projection (MIP ) and the volume of processing (VR) and other post-processing. Results 15 cases were a good demonstration of the entire aorta and its branches, true cavity, false lumen, intimal flap, and dissection of the location, extent satisfactory display. Conclusion MSCTA diagnosis of dissecting aneurysm of accurate, quick and effective method of choice for examination, with a high clinical value. [Keywords:] Aneurysm, dissecting; tomography, spiral computed; Angiography The utilization of multislice spiral CT angiography in aneurysm of aorta LUO Lin, ZHU Yong  hua, MU Qing  jin.et al.CT Room, Department of Radiology, The First People’s Hospital, Qujing 655000, China [Abstract] Objective To investigate the value of multislice spiral CT angiography (MSCTA) for the diagonosis and treatment of disseting aneutysm of aorta.Methods MSCT for chest and belly scanning and enhanced scanning was performed in 15 patients and the data was transferred to SGI workstation for image post processing including MPR, SSD, MIP and VR (4D  Angio). Results The whole aorta and branches in 15 patients were displayed well by MSCTA.The true lumen, false lumen, intimal flap, location and extend of dissecting aneurysm were showed in all psatients satisfactorily.Conclusion MSCTA is accurate, fast and effective for the diagnosis of dissecting aneutysm. [Keywords:] aneurysm, dissecting; tomography, spiral computer; angio

您可能关注的文档

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档