网站大量收购独家精品文档,联系QQ:2885784924

Multi-slice spiral CT perfusion imaging in the diagnosis of thyroid lesions.doc

Multi-slice spiral CT perfusion imaging in the diagnosis of thyroid lesions.doc

  1. 1、本文档共11页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Multi-slice spiral CT perfusion imaging in the diagnosis of thyroid lesions

 PAGE \* MERGEFORMAT 11 Multi-slice spiral CT perfusion imaging in the diagnosis of thyroid lesions [Abstract] Objective To study the multi-slice spiral CT perfusion imaging in the diagnosis of thyroid diseases. Methods 21 cases of normal thyroid, 32 cases of thyroid cancer, 69 cases of benign lesions (31 cases of thyroid adenoma, nodular goiter, 38 cases MSCT perfusion imaging, using CT perfusion 2 software to analyze blood flow perfusion parameters (BF, blood volume (BV, mean transit time (MTT, and permeability surface (PS, on average, and statistically analyzed. Results normal thyroid group BF, BV , MTT, and PS, respectively (549.61 + -187.91) mL 100 g-1 min-1, (9.34 + -3.41) mL/100 g, (2.65 + -0.97) s, (36.07 + -25.11) mL 100 g-1 min-1, thyroid cancer group were (326.81 + -139.14) mL 100 g-1 min-1, (7.95 + -5.65) mL/100 g, (3.90 + -2.60) s, (54.06 + -22.95) mL 100 g-1 min-1, benign lesions were (330.53 + -144.02) mL 100 g-1 min-1, (8.14 + -5.33) mL/100 g, (3.87 + -2.56) s, (41.84 + -24.54) mL 100 g-1 min-1.3 between groups, BF, PS statistically significant difference between the value of (P = 0.001,0.018), BV, MTT values no significant difference (P = 0.586,0.093). BF value of each group every two, the normal group and the BF value of the difference between benign and malignant groups was statistically significant (P = 0.000,0.001), benign and malignant groups was no significant difference (P = 1.000.PS value of the malignant group and the normal group, a statistically significant difference between the benign group (P = 0.009,0.020), difference between normal group and benign group was no significant difference (P = 0.341. Conclusion MSCT perfusion imaging perfusion PS values of parameters of benign and malignant thyroid lesions to determine a certain value. [Keywords:] thyroid disease, tomography, spiral computed, perfusion, regional CT perfusion imaging as a means of functional imaging, and its application in the brain has matured, i

您可能关注的文档

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档