Multiple injuries in the spiral CT contrast agent enhanced MRI application and security management.doc
- 1、本文档共15页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Multiple injuries in the spiral CT contrast agent enhanced MRI application and security management
PAGE \* MERGEFORMAT 15
Multiple injuries in the spiral CT contrast agent enhanced MRI application and security management
Of: Li Xue, Zhang Weiguo, Chen Rong, Ran Qisheng, Chen Jinhua
[Abstract] Objective To investigate the multiple trauma spiral CT enhanced MRI in the iodine contrast agent application and security management. Methods A retrospective analysis in January 2009 ~ March 2010 spiral CT enhanced MRI of the 134 cases of multiple trauma patients, male, 106 cases 28 girls; aged 2 to 82 years old, average 42.5 years old. 55 cases of road traffic injuries, stab wound in 15 cases, 39 cases of fall injury, injured in 25 cases. contrast agent used mainly Omnipaque (350mgI/ml), Ultravist (370mgI/ml), three generations were (350mgI/ml), the amount of 1.5 ~ 2ml/kg, injection rate 3.0 ~ 4.0ml / s. enhance the development of multiple trauma CT examination process, vital signs were observed during the examination and other adverse reaction. Results enhanced spiral CT scan of new blood vessels and other damage found in 59 patients meeting; 5 cases of contrast injection heart rate, breathing faster, but the blood pressure is stable and 129 patients without significant changes in vital signs; no nausea, vomiting, skin rashes and other symptoms of adverse reactions .2 with the difficult cases because of restlessness, sedation underwent enhanced spiral CT examination, resulting in prolonged examination time, the 132 patients in the 8 to 10 minutes successfully completed examination. Conclusion multiple trauma enhanced spiral CT examination of blood vessels and help to identify real of organ damage, the above three kinds of contrast agents safe and effective.
[Keywords:] multiple trauma; spiral CT; iodine contrast agent
[Abstract] Objective To investigate the security management of contrast agent in spiral CT enhancement of multiple injuries.Methods Totally 134 cases of multiple injuries who had spiral CT enhancement scanning during Jan.2009 to Mar.2010 wer
您可能关注的文档
- Mrs. Le's 'fresh strategy'.doc
- Mrs. oral solution T191 and orange time.doc
- Mrs. Wang's multiple choice.doc
- MRU in the diagnosis of urinary tract obstruction cause the application of research.doc
- MRSA-PBP2a monoclonal antibody latex agglutination assay for the establishment of.doc
- MS Contin treatment of pain in 82 cases of dose distribution analysis of.doc
- MS Contin treatment of severe pain in advanced cancer of 65 cases.doc
- MS Contin with transdermal fentanyl in the treatment of moderate to severe pain in the observation of.doc
- MSA after the tobacco marketing strategy.doc
- MSCT efficacy in the treatment of fatty liver of the quantitative role.doc
最近下载
- 2022急诊胸痛心血管标志物联合检测专家共识(全文).pdf VIP
- 2025年四川高处安装、维护、拆除作业_特种作业证考试复习题库资料(含答案).pdf
- 临床医学专业水平测试评分表.pdf VIP
- 2024年四川省绵阳市中考化学真题卷(含答案与解析).pdf VIP
- 《三位数乘两位数》大单元教学设计 (1).docx VIP
- 2024年四川省绵阳市中考数学真题卷(含答案与解析).pdf VIP
- 生如夏花小清新模板(含音频+视频).pptx VIP
- 2024学年统编版高中语文选择性必修下册《客至》优质课一等奖课件28张.pptx
- Sysmex XN-1000全自动血液分析仪标准操作程序.pdf VIP
- 2025安全生产月主题宣讲课件.pptx
文档评论(0)