Non-contact life parameter detection system dynamic - static target recognition technology.doc
- 1、本文档共13页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Non-contact life parameter detection system dynamic - static target recognition technology
PAGE \* MERGEFORMAT 13
Non-contact life parameter detection system dynamic / static target recognition technology
[Keywords:] Fast Fourier Transform
Technology for motional / motionless object recognition in noncontact lifeparameter detecting system
[Abstract] AIM: To offer more object information to the rescue team by recognizing the motional / motionless state of an object in the detecting range of a noncontact lifeparameter detecting system. METHODS: After extracting the respiration signals and the body signals, we compared the frequency domain energy of the signals with the threshold by a method based on Fast Fourier Transform (FFT). RESULTS: In human detecting experiment of 20 cm and 30 cm thick wall, the motional / motionless state of an object was found to be well related to the energy ratio between the respiration signals and body signals within the detecting range of the system. CONCLUSION: This method can be used by noncontact lifeparameter detecting system in different detecting conditions and can rapidly recognize the motional / motionless state of an object, thus enhancing the function of the system.
[Keywords] object recognition; fast fourier transform; energy ratio; threshold; Delphi
[Abstract] Objective: To identify the non-contact life parameter detection system to detect movement within the target / quiescent state, in order to provide a richer exploration target information. Methods: Extraction System to detect respiratory signals and body movement signals, select the most excellent data on the length of each fast Fourier transform (FFT), two pairs of the transformed signals in frequency domain analysis and comparison of energy, taking into account the threshold set by the Department. Results: 20 cm and 30 cm experiments show that people pass through the wall probe in the system’s detection range, the target movement / static Zhuang state and respiratory signals and body movement signals in frequency domain energy than have a good corre
您可能关注的文档
- Niuhuangjiedu multi-layer tablets.doc
- Nivea How to scatter seeds which become soldiers-.doc
- NKG2D-mediated NK cell killing effect of nasopharyngeal carcinoma cells in vitro.doc
- NK cells and recurrent spontaneous abortion maternal-fetal immune disorder.doc
- NK leukemia immunophenotypic characteristics.doc
- NLM information services and discussion of the evolution strategy.doc
- NLM information services and discussion of the evolution strategy_0.doc
- NK cells in human nasopharyngeal carcinoma cells in nude mice transplanted tumor CNE2 inhibition of.doc
- Nitrous oxide on tracheal tube and laryngeal mask sets of intracapsular pressure.doc
- NLM information services of Strategic Analysis and Evolution.doc
- Non-contact mapping to guide left ventricular catheter ablation of idiopathic ventricular tachycardia.doc
- Non-contact mapping identified the right ventricular outflow tract tachycardia and diastolic triggered activity and export endometrial.doc
- Non-deposition and blood circulation disorders of Huayu law in women's health care in the use of health Totale.doc
- Non-degenerative lumbar disc disease and its treatment as defined.doc
- Non-diabetic patients with metabolic syndrome the change of adiponectin levels and insulin resistance in study.doc
- Non-diabetic stress hyperglycemia on acute short-term prognosis of myocardial infarction.doc
- Non-drug treatment for hypertension Research.doc
- Non-fried camp fame and tragedy.doc
- Non-frame ultrasound-guided puncture percutaneous ureteroscopy in the establishment of the value of micro-channel.doc
- Non-destructive optical measurement of gastric organization KTP - Nd- YAG laser optical properties of the difference.doc
最近下载
- 三年高考2024_2025高考生物真题分项汇编专题13生态系统与环境保护含解析.doc VIP
- 教学资源创新落体缓降(课件)小学科学科普 通用版.pptx
- 淮阴区村干部资格认证考试试题.pdf VIP
- 10J012-4 环境景观-滨水工程.docx VIP
- 设备拆卸高压水去污小室sbe209ba运行维护手册.pdf VIP
- 【2025.5高三二模】昌平数学试题.docx VIP
- 工程勘察服务成本要素信息(2022版).docx VIP
- 审计工作底稿系列表格 .pdf VIP
- SLT 631.1-2025 水利水电工程单元工程施工质量验收标准 第1部分:土石方工程.docx
- 吴必虎-旅游学概论(第二版)03 第三章 旅游产品与供给.ppt VIP
文档评论(0)