网站大量收购独家精品文档,联系QQ:2885784924

Of cervical cancer brachytherapy treatment of three-dimensional dose distribution verification.doc

Of cervical cancer brachytherapy treatment of three-dimensional dose distribution verification.doc

  1. 1、本文档共12页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Of cervical cancer brachytherapy treatment of three-dimensional dose distribution verification

 PAGE \* MERGEFORMAT 12 Of cervical cancer brachytherapy treatment of three-dimensional dose distribution verification [Keywords:] Cervical cancer Detection of 3Ddose distribution of intracavitary brachytherapy for cervical cancer patients [Abstract] AIM: To investigate the feasibility of checking the 3Ddose distributions of intracavitary brachytherapy for cervical cancer patients by thermoluminescent dosimeter (TLD) [LIF (Mg.Cu.P)] in an anthropomorphic pelvic phantom. METHODS: On the basis of a simulated intracavitary brachytherapy plan, TLD components were put into test holes in anthropomorphic pelvic phantom for measuring the dose to each TLD component with FJ427A1 dosimeter following the intracavitary irradiation with MicroSelectron HDR afterloader at the prescription dose. The measured values were compared with the calculated ones. RESULTS: A good linear relationship was found between the TLD components measured values and the irradiation doses within the range of 0-300 cGy, and the former ones were in a good line with the calculated ones with 3DVTPS at the reference points of A, B , F, bladder and rectal doses, average error being ± 5.16%. CONCLUSION: TLD components tested doses can well reflect the exposure doses of patients, so it is of important value to forecast radiotherapy side effects, optimize radiotherapy plan and improve curative effect. [Keywords] cervix neoplasms; radiotherapy; thermoluminescence dosimeter [Abstract] Objective: To Chengdu pelvic model and simulation of human LIF (Mg.Cu.P) thermoluminescence dosimeter (TLD) intracavitary brachytherapy for cervical cancer verify 3D dose distribution is feasible. Methods: Based on the clinical intracavitary radiation therapy simulation programs installed programs, set within a simulation model of the human pelvic reference points (holes), the TLD element into the simulation model of the human pelvic test hole, with MicroSelectron HDR brachytherapy machine simulation program according to th

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档