- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
修建疏散标准条例(国外英文资料)
建筑疏散规范条例(国外英文资料)
Safe exits are dispersed in different directions. The safe evacuation distance shall meet the following rules:
The distance from the distance to the room is not more than 15m.
The maximum distance from the door to the nearest safe exit: the hospital should be 24m; The hotel should be 30 m; Other projects should be 40m. The maximum distance should not exceed half of the corresponding distance between the two sides of the bag-shaped walkway
The number of evacuated people in the shop should be calculated according to the floor area of each floor and the area of the area. The area discount of floor shop is 50 ~ 70%, the area of underground shop should not be less than 70%. The reduction of the number of evacuees can be determined by the table 5.3.17-2.
Table 5.3.17-1 evacuation walkways, safe exits, evacuation staircases and room evacuation doors for every 100 people (m)
Floor location fire resistance level
One, two level three levels four
The ground one, two floors 0.65 0.75 1.00
On the ground three levels 0.75 1.00 -
Four or more layers above ground 1.00 1.25 -
No more than 10 megabytes of underground buildings are below the surface of the ground
A height of more than 10 megabytes above the surface of the ground
Table 5.3.17-2 the conversion factor (man/m2) in the shop room
Floor below ground floor below ground level, ground first, floor layer of layer 3 above ground level 4 and above all levels
The conversion factor was 0.80 0.85 0.77 0.60
According to code for fire protection design of tall buildings of the provisions of article 6.2.9 each layer of the evacuation stairs every 100 the number of total width should be according to its by not less than 1.00 m, the number of layers are not equal, the total width can be segmented, evacuation stair lower total width shall be calculated on the upper most layer. The minimum width of evacuation stair should not be less than the provisions of the table 6.2.9. But the net width should not be less than 1.20 m.
您可能关注的文档
最近下载
- 金顺电子材料产业园环境影响报告表.docx VIP
- 化工原理练习与答案.doc
- (正式版)D-L∕T 801-2010 大型发电机内冷却水质及系统技术要求.docx VIP
- 《心理危机与日常调适:写给少年们的10封信》随笔.docx VIP
- 〖GB50157-2013〗地铁设计规范.docx VIP
- 2025年中考英语听力技巧与策略教学+课件.pptx VIP
- 辽2015J601 楼梯标准图集.docx
- 景观桥亮化施工方案.docx
- -求数列通项公式的方法总结ppt(11种方法举例)-.docx VIP
- 第7课+全球联系的初步建立与世界格局的演变 高一下学期统编版必修中外历史纲要下.pptx VIP
文档评论(0)