房建试题(国外英文资料).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
房建试题(国外英文资料)

房建试题(国外英文资料) The building project safety quality basic management test (A) (A) Unit: name: position: The topic purpose A, single topic selection Second, the true or false Three, the paper topic As a performance Standard score 40 20 40 Get points One, single choice: (20 questions, 2 points per question) The main vertical bar spacing should not be greater than () when the frame column of steel pipe is used. A. 0.5 m B 2, USES the fastener type steel pipe scaffold templates scaffolding, standing pole must be set at the bottom of the vertical and horizontal sweep the floor, under the vertical and in horizontal, using right-angle fastener, fastened up the limit height of the vertical sweeping bar from base for (A) A. 200mm b. 250mm c. 300mm The butt of the vertical bar (the great cross bar) should meet the following rules: (A) A. should be staggered, two adjacent rod joint, at the levels of sync or across different release stagger distance should be not less than 500 mm, the joint center nearest the master node distance not greater than 1/3 of the longitudinal spacing B. The joint of two adjacent poles should be in the same step and the same span C. the joint of two adjacent poles can be in the same vertical plane The joint of two adjacent poles can be within 200mm in the horizontal direction When the scaffold is segmented, and when the separation is dismantled, the scaffold shall be (A). A: it is necessary to set up the wall and horizontal brace on both ends B. no reinforcement You dont have to have a wall D. set up unloading measures The temporary electric power and the lighting distribution shall be set up. The distance between the distribution box and the switch box shall not exceed (A); The level of the switch box should not exceed the level of the power equipment controlled by (A) m. A. 30. B. 20 m, 3 m; C. 15 m, 10 m; When the power distribution or distribution line is out of power, the grounding line should be suspended and the power failure sign should be suspen

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档