准确肯定框架—剪力墙结构中各分部结构的抗震等级(国外英文资料).doc

准确肯定框架—剪力墙结构中各分部结构的抗震等级(国外英文资料).doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
准确肯定框架—剪力墙结构中各分部结构的抗震等级(国外英文资料)

准确确定框架—剪力墙结构中各分部结构的抗震等级(国外英文资料) Framework-shear wall structure is a common form of architectural engineering. Frame - shear wall structure of frame and shear wall of earthquake overturning moment and the total structure seismic overturning moment ratio is to determine the important basis of frame and shear wall seismic grade. To this, the code for seismic design of buildings GB50011-2001 article also 6.1.3 and JGJ3-2002 technical specification for concrete structures of tall building 8.1.3 article made specific provision, how to understand the standard clauses spirit, accurately determine the seismic grade of frame and shear wall, to ensure the quality of the design of the reinforced concrete frame shear wall structure, the structure design is often deal with the problem. Here are some of my personal insights. GB50011-2001 specification also 6.1.3 rule: frame - shear wall structure, under the influence of the basic mode, if the earthquake overturning part under the framework of greater than 50% of the total seismic overturning structure, the frame part of the seismic grade is determined according to the frame structure, and the biggest apply appropriately increased highly comparable frame structure. JGJ3-2002 article 8.1.3 norms, seismic design of frame - shear wall structure, the basic mode under the action of earthquake, earthquake overturning part under the framework of greater than 50% of the total seismic overturning moment when structure, the frame part of the seismic grade should be used according to the frame structure; its maximum height and apply appropriate ratio than frame structure increase. The spirit of the two is consistent. According to the spirit of the above provisions, reinforced concrete frame - shear wall structure design, the first part should be based on frame under earthquake overturning moment what percentage of total seismic overturning moment, determine the respective frame shear wall seismic grade. Often, first trial in accordance with

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档