混凝土梁板柱模板除往计划(国外英文资料)
混凝土梁板柱模板拆除方案(国外英文资料)
Construction plan for concrete beams, plates and columns
Construction measures for the demolition of the template
1, the bearing side form (wall of die and mould and beam side die) should be to ensure the concrete surface and the edges are not subject to damage (greater than 1.2 MPa) to dismantle, about 24 h ~ 36 h, determined by block with conditions.
The condition of the construction of the bearing form (girder, board and bottom die) shall be carried out according to the quality acceptance specification of the construction quality of concrete structures (gb5020204-2002). Concrete pouring over a period of time, sending with curing of concrete block under the condition of laboratory test, according to the strength of the laboratory to issue report, determines the time of the template and measures, by the technical director to issue notice to dismantle, can tear open mold.
3, the order of the removal of the template is the reverse of the order in which the template is installed.
(1) the column template is removed
After the concrete strength reaches 1.2 Mpa, the column can be removed when the surface and Angle are not damaged. Mould demolition, the first dismantled rod or brace, then top-down, dismantling column hoop to demolish part shaft and finally carefully with the template from flowing to the outside with a crowbar or gently pry the tap, to loosen the template from column concrete, demolition of people standing in the operation on the shelf, can not stand on the template. It is strictly forbidden to use hard pry so as not to injure the corners of the concrete and prevent the deformation of the form. The column of the demolition leans on the outer shelf in turn, and when the entire column template is removed, the template is shipped in time.
Floor die and floor plate are removed
The beam and floor template should be removed first, then the bottom die of the floor and the bottom die. The order is as follows: