家装隐蔽工程的验收(国外英文资料)

家装隐蔽工程的验收(国外英文资料) We put 10 centimeters of water in the room, and we have to make sure that the water is highly labeled. Third step, 24 hours after acceptance personnel to observe whether the water height is changed, and also check whether the ceiling of the room downstairs in the same position in water seepage phenomenon; In the fourth step, if there is no such phenomenon, the inspection and acceptance personnel may consider the construction of waterproof construction to be acceptable; On the other hand, if the above phenomenon is detected by examination, it is considered that waterproof construction is not up to standard. If the acceptance fails, the waterproof project must be redone, and the acceptance shall be re-examined. For light wall waterproofing construction of acceptance, should be taken to drench water test, which USES water in well waterproof coating on the metope of top-down uninterrupted spray for 3 minutes, 4 hours, observe whether the other side of the wall will appear osmosis phenomenon, if no infiltration phenomenon appear to think metope waterproof construction acceptance. Tip: the first step on the ground is what we call a closed-water test. Since light body wall is prone to leakage, and routine check is easy to miss, it must also be waterproof. The acceptance of the noil distribution project: The acceptance of waterproof project, in order not to let the water leaking out, and power distribution lines of acceptance in order to make clear, not appear short circuit and open circuit phenomenon. The acceptance personnel should check the following items in order of priority: Whether the various materials used in the design conform to the design requirements; Whether the line is fixed; (3) whether the line connection is strong; 4, does the wire have a connection and the joints are strong? If there is a connection between the cable and the cable, if there is a connection, it must be replaced, or use a splitter in the receiver. If there is a connection

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档