线艺开关变压器结构设计指南-StructuredDesignofSwitching详解
Structured Design
of Switching Power
Transformers
Transformer Design Procedure
Design of switching power transformers can be accom- mine N . This value for N should allow non-saturating
P P
plished in a relatively simple manner by limiting magnetic operation to 100°C with reasonable core loss.
configurations to a few core and coilform structures.
These structures have been chosen both for their versatil- Step 3. Secondary turn count
ity and their low cost. Dimensional information as well as
Secondary turn count is a function of duty cycle and
design information in the form of design curves for the
primary turn count.
chosen structures may be found at the end of this docu-
ment. By using these curves, the complete transformer For a flyback system:
can be designed.
(2)
Step 1. Structure size For a forward converter:
The first step in the design is choosing a minimum struc-
ture size consistent with the output power required. The
(3)
approximate power capabilities of each structure are
provided in Table 1. If five or six outputs are required, Where:
a larger structure may be required to allow the copper NP = the primary turn count.
along with insulation and winding crossovers to fit in the NS = the secondary turn count.