发电机的试验要求(国外英文资料)
发电机的试验要求(国外英文资料)
4 test instrument with 4.1 meter sensor with sensor test instrument used by sensors should be certified by the department of measurement and in the period of validity, instrument with sensor test range, accuracy should be operator testing requirements and the provisions of the relevant standards instrument with the accuracy of the sensor shall be not less than 0.2 on the Richter scale are unlikely. 4.2 instrument test using instrument, shall be certified by the department of measurement and in the period of validity, the test using test range, precision instruments and meters in accordance with the test requirements and the provisions of the relevant standard. Test, adopt the accuracy of electrical measuring instruments shall be not less than 0.5 (with the exception of megger), and the accuracy of resistance measuring instrument shall be not less than 0.2, the accuracy of torque measuring instrument shall be not less than 0.5, the accuracy of tachometer shall be not less than 1.0 on the Richter scale, dynamometer of quasi 2 NB/T XXXX. 2, the accuracy of the x x x x should be not less than 1.0 (with the exception of hanging spring balance), and the error of the thermometer is not greater than soil l ℃. Test equipment and circuit should meet the requirements of the test. Before the test, participants generator should be in normal state, the connection is correct, try to be the generator assembly and check the running status, in order to protect the various test can run smoothly. The 4.4 safety measures, which involve dangerous current, voltage and mechanical force, should take safety precautions for all trials. All trials should be operated by a person with knowledge and experience. 5 pilot project 5.1 measuring 5.1.1 winding insulation resistance of casing and the determination of winding insulation resistance between 5.1.1.1 motor state measurement of the motor winding insulation resistance should be in real cold state and hot state machine (or) aft
文档评论(0)