网站大量收购独家精品文档,联系QQ:2885784924

压力传感器输进旌旗灯号不稳旌旗灯号的弊病剖析(国外英语资料).doc

压力传感器输进旌旗灯号不稳旌旗灯号的弊病剖析(国外英语资料).doc

  1. 1、本文档共4页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
压力传感器输进旌旗灯号不稳旌旗灯号的弊病剖析(国外英语资料)

压力传感器输出信号不稳信号的故障分析 Fault analysis of unstable signal of output signal of pressure sensor The output of the pressure transmitter is not changed, the output of the pressure transmitter is changed suddenly, and the zero position of the pressure relief transmitter can not be returned. The reason of this phenomenon is most likely caused by the pressure sensor ring, usually because of seal specifications reasons (too soft or too thick), tighten the sensor, the sealing ring is compressed to the pressure sensor inside the mouth jam sensor. The pressure up, this situation not to output, should first check the pressure interface is leaking or blocked, if not, check the connection mode, if the wiring is correct then check the power supply, such as the power supply is normal again on the sensor zero if there is output, or simply to see whether the output pressure change, change that sensor is not damaged if there is no change, the sensor has been damaged. Other reasons for this may be instrument damage or other aspects of the system. The pressure when the pressure medium to go in, but a lot of pressure when suddenly rushed to open the sealing ring, the pressure sensor by pressure changes, while the pressure decreased again when the sealing ring is also blocked the return pressure, residual pressure release out, so the sensor zero down again. The best way to remove this reason is to remove the sensor, check whether the zero is normal, and if you change the seal, try again. The output signal of transmitter is unstable and the reason of unstable signal is as follows: The A. pressure source is itself an unstable pressure B. instrument or pressure sensor anti-interference ability is not strong? The C. sensor is out of wiring The D. sensor itself is very vibrating The E. sensor fault transmitter has no output power possible: F. connect the wrong line (both instrument and sensor should be checked) G. the wire itself is broken or shorted H. power supply, no output or power mismatch I.

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档