压力传感器输进旌旗灯号不稳旌旗灯号的弊病剖析(国外英语资料)
压力传感器输出信号不稳信号的故障分析
Fault analysis of unstable signal of output signal of pressure sensor
The output of the pressure transmitter is not changed, the output of the pressure transmitter is changed suddenly, and the zero position of the pressure relief transmitter can not be returned. The reason of this phenomenon is most likely caused by the pressure sensor ring, usually because of seal specifications reasons (too soft or too thick), tighten the sensor, the sealing ring is compressed to the pressure sensor inside the mouth jam sensor.
The pressure up, this situation not to output, should first check the pressure interface is leaking or blocked, if not, check the connection mode, if the wiring is correct then check the power supply, such as the power supply is normal again on the sensor zero if there is output, or simply to see whether the output pressure change, change that sensor is not damaged if there is no change, the sensor has been damaged. Other reasons for this may be instrument damage or other aspects of the system.
The pressure when the pressure medium to go in, but a lot of pressure when suddenly rushed to open the sealing ring, the pressure sensor by pressure changes, while the pressure decreased again when the sealing ring is also blocked the return pressure, residual pressure release out, so the sensor zero down again. The best way to remove this reason is to remove the sensor, check whether the zero is normal, and if you change the seal, try again.
The output signal of transmitter is unstable and the reason of unstable signal is as follows:
The A. pressure source is itself an unstable pressure
B. instrument or pressure sensor anti-interference ability is not strong?
The C. sensor is out of wiring
The D. sensor itself is very vibrating
The E. sensor fault transmitter has no output power possible:
F. connect the wrong line (both instrument and sensor should be checked)
G. the wire itself is broken or shorted
H. power supply, no output or power mismatch
I.
您可能关注的文档
最近下载
- 2022急诊胸痛心血管标志物联合检测专家共识(全文).pdf VIP
- 2025年四川高处安装、维护、拆除作业_特种作业证考试复习题库资料(含答案).pdf
- 临床医学专业水平测试评分表.pdf VIP
- 2024年四川省绵阳市中考化学真题卷(含答案与解析).pdf VIP
- 《三位数乘两位数》大单元教学设计 (1).docx VIP
- 2024年四川省绵阳市中考数学真题卷(含答案与解析).pdf VIP
- 生如夏花小清新模板(含音频+视频).pptx VIP
- 2024学年统编版高中语文选择性必修下册《客至》优质课一等奖课件28张.pptx
- Sysmex XN-1000全自动血液分析仪标准操作程序.pdf VIP
- 2025安全生产月主题宣讲课件.pptx
文档评论(0)