5 剧场建筑设计规范(外国英语资料)
5 剧场建筑设计规范
The size of 1.0.4 theatre can be divided into capacity according to auditorium capacity:
Extra large, over 1601 seats;
Large 1201 - 1600 seat;
Medium size 801 - 1200 seat;
Small 300-800 seat.
Drama and opera theatre should not exceed 1200. The song and dance theatre should be no more than 1800.
The 3.0.2 theater base should have at least one open space facing the town or directly leading to the city road. The accessible width of the urban road shall not be less than the sum of the width of the safety exit of the theater, and shall comply with the following provisions:
Less than 800 seats should not be less than 8m;
801-1200 seats should not be less than 12m;
More than 1201, should not be less than 15m.
4.0.6 theater audience should be set to use the toilet, the toilet room should be set up. The toilet door shall not be opened to the auditorium. The ratio of men to toilet toilets is 1:1, and sanitary appliances shall meet the following requirements:
(1): men should be provided with a toilet every 100 seat, a urinal or 0.6m long urinal every 40 seat, 150 seat is provided with a wash basin;
(2) womens toilets: one stool should be set for every 25, and one wash basin for every 150;
(3) toilets for men and women shall be provided with special toilet for disabled persons.
5.1, 1 line of sight design should allow the audience to see the whole of the stage performance area. When conditions are limited, visual quality should also be poor, and spectators at the venue can see 80% performance areas.
The choice of 5.1.2 viewpoint shall comply with the following provisions:
The proscenium theatre stage should be selected in the proscenium line at the center table;
When conditions are limited, the design viewpoint can be improved appropriately, but not more than the stage 0.3m; and the rear edge of the large screen projection line should not be greater than 1m.
5.1, 3 eye elevation, the design should comply with the following requirements:
Line of sight elevation diff