安规问答题
1. what are the basic requirements for the operators?
1.1. is certified by a doctor without symptoms of obstruction to work
1.2. have the necessary electrical knowledge and business skills, and be familiar with the relevant parts of the procedures according to the nature of the work, and have passed the examination
1.3. have the necessary electrical safety knowledge, learn emergency ambulance law, especially to learn electric shock first aid
2. any person who finds any violation of these Regulations shall immediately stop it and correct it before it can resume its operation. All types of operating personnel have the right to refuse to command and command dangerous operations
3. what is high voltage electrical equipment? What is low voltage electrical equipment?
3.1. high voltage electrical equipment: voltage class 1000V or above
3.2. low voltage electrical equipment: voltage class 1000V and below
4. no matter whether the high-voltage equipment is electrified or not, the staff shall not remove or work over the barrier separately. If necessary, when removing the barrier, there shall be a guardian present and comply with the safe distance of table 2-1
5. what are the requirements for inspection of high voltage equipment?
5.1. approved by the unit of separate visits of high voltage equipment inspection personnel of high voltage equipment, no other work, shall not be removed or over the block.
5.2. thunderstorm weather, need to check for outdoor high-voltage equipment, should wear insulated boots, and may not be close to the lightning arrester and the lightning rod.
When 5.3., fire, earthquake, typhoon, flood and other disasters occur, if the equipment is to be visited, the equipment operation management unit shall be approved by the relevant leaders, and the patrol personnel shall maintain communication and liaison with the dispatched departments
5.4. high voltage equipment grounding, do not close to the fault point within 4 meters, the outdoor may not be close to