- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
                        查看更多
                        
                    
                水利工程概论 16
                    Chapter 13 Pumping stations Lecture 13th  Introduction to course The teacher Introduction to course The teacher Fig.13.13 Effect of booster pump on gravity line Introduction to course Pumping stations for water supply from river intakes or boreholes are normally designed to discharge continuously over a period of 20-22h a day. Boosters may also need storage facilities. It is advisable to install more than one pump so that maintenance may be carried out without interrupting the supply. Often, several pumps of differing capacities are installed in a water supply pumping station, and the units are switched on or off as demand variations dictate. If a very fine controlled output is needed, variable-speed motors (expensive) must be used. Sewage pumps must be so designed as to be capable of pumping the peak flows as they occur in sewers, with a maximum delay of no more than 12h. Otherwise, the sewage may become septic. The flows may vary considerably throughout the year, month, week or day. The daily variations may be considered to be between zero (at night) to about six times the dry weather flow (d.w.f.) at times during the day, and it is preferable to install pumping capacity up to 6 d.w.f. using at least two or three pumps, each capable of about 2 d.w.f. Pumping mains are usually designed for velocities of around 0.9-1ms-1 when supplying water at a constant rate throughout the day. This may be doubled for short-period pumping. Prior to the final selection of the pipeline diameter, economical analyses balancing the costs of large-diameter pipelines and their maintenance, and the savings in pumping costs due to the reduction in friction losses, must be carried out. The minimum diameter suitable for pumping unscreened crude sewage is 100mm and velocities around 0.75-2ms-1 are normally recommended. However, in stormwater-sewage pumping higher velocities (even 3-4ms-1) may be more economical as their operation is intermittent. The friction head losses in the case of sludge
                 原创力文档
原创力文档 
                        

文档评论(0)