- 1、本文档共8页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
JCCAD——2_基础人机交互输入(JCCAD - 2_ basic human-computer interaction input)
JCCAD——2_基础人机交互输入(JCCAD - 2_ basic human-computer interaction input)
JCCAD - 2. Basic man-machine interactive input JCCAD JCCAD application ning company structure design blog registration set as home page to help home | | | | blog group commune column BBS blog friends | | | | picture mall broadcast contribute | | random access | subscription
Subscriber list
Secret code forget password
Save the password
Subscriber list
Secret code forget password
Save the password
The nning structural design blog copies the personal data log picture video (survey) friend blog group encyclopedia my journal JCCAD -- 2. Basic human-computer interaction typing classification: JCCAD application 2006.8.2
15:29 author: burning cigarette ash | comments: 0 | reading: 4797
JCCAD -- 2. Basic human-computer interaction input
Geological data
Enter *.dz files, and the mobile grid is the same as the actual situation.
Parameter input
Basic parameters
1. Calculation parameters of foundation bearing capacity
A. Foundation embedded depth (unit m) :
Generally from outdoor ground elevation calculation; For the basement, the raft foundation should also be calculated from the outdoor ground elevation. Other such as the base, the sole basis, the beam foundation from the indoor ground elevation calculation. (the base of the basement should be counted from the indoor ground level.) This value is used to correct foundation bearing capacity.
B. automatic overburden:
It refers to the ratio of the soil weight and the base area to the base area. It is used for the sole base and the base, and automatically calculates by 20kn/m * m after check. If you do not check, you should fill in the soil weight (kn/m * m) manually. When the base and the sole have a basement, they should be filled in manually, and the soil height is calculated to the basement floor.
2. Basic design parameters
A. Girder assumes a bending moment ratio: 0.5, 1, 0
B. concrete c30
C. Importance coefficient: according to the specification, single pil
您可能关注的文档
- (万科)住宅设计统一技术措施(建筑)(Unified technical measures for residential design (construction)).doc
- (建筑工程)第1章3(Chapter 1, 3).doc
- (新版)收缩膜热收缩膜生产制备工艺及应用专利技术光盘((new) shrink film shrinkage film production preparation process and application of patented technology compact disc).doc
- -平面旋转LED点阵套件-电子制作(- plane rotating LED lattice kit - electronic production).doc
- 001世界十大宫殿(001 the world's ten palaces).doc
- 0.8QQ手挡驾驶全攻略(0.8 QQ hand in the driver overall strategy).doc
- 002机械挖土施工工艺(Construction technology of mechanical excavation).doc
- 002作图题(黄冈市物理中考题调考题汇编)(002 graph (a compilation of examination questions in the physics of huanggang)).doc
- 008年石家庄市第二十八中学初三年级一模考试(In 008 shijiazhuang no.28 middle school, the first third grade a module examination).doc
- 005机械回填土施工工艺(Construction technology of mechanical backfill soil).doc
文档评论(0)