abaqus问答精华(ABAQUS question and answer essence).docVIP

abaqus问答精华(ABAQUS question and answer essence).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
abaqus问答精华(ABAQUS question and answer essence)

abaqus问答精华(ABAQUS question and answer essence) Q: pre tensioned prestressed reinforced how, please pointing. Q: I see in the document that you want to define a rebar in the InP file, but rebar can only be used for shell, membrane, and, solid, elements. I want to do now is a prestressed cable, not embedded in the shell, membrane, and solid the unit, a zipper but independent. The cable unit is going to use truss, but how do you use rebar on the truss? Please expert pointing Another problem, I see someone elses InP file, is as follows: *rebar, element=continuum, material=rebar2, name=ubar Top1,1.005e-4,0.15,0.0,0.5,1 The second line, the first is setname (Top1), and the second is the cross-sectional area (1.005e-4) of the rebar. What do the third, fourth and fifth mean? (0.15,0,0.5) the last one should be the direction, the 1 direction. Which expert pointed out the first three or four and five respectively? A: exerts prestressing force *initinial, conditions, type=stress, rebar Elset, rebar name, the prestress value, the other prestress hold to keep the prestress value unchanged, my understanding is to prevent other members eat the prestress, caused by prestress loss. With this command, this loss is avoided, and the applied prestressing force is applied to the reinforcement. A: thank you, what you say should be put in prestressed rebar above, but I find that the truss unit cannot be defined as rebar, in fact, I think that truss would have when cable engineering prestressed steel strand tension is to play a role, tension, and in ABAQUS, truss itself is taut, without prestress A: I know simulation reinforced when the need to use rebar, but the bar you can do directly with truss to simulate, and LZ said actually just during the construction of prestressed tension is not the real meaning of prestress, such as prestressed bolt etc.. If it is a cable, it may be a mere personal view of the prestressing force. Q: ask: do a space steel frame structure, beam column with beam ele

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档