PKPM错层建模问题[1](PKPM fault layer modeling problem [1]).docVIP

PKPM错层建模问题[1](PKPM fault layer modeling problem [1]).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
PKPM错层建模问题[1](PKPM fault layer modeling problem [1]) = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = page 1 = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = 1. Problems encountered during modeling 1. The structure with the wrong layer (frame structure) PKPM In the middle, the so-called wrong layer refers to the distance between the floors Higher than a beam (generally) 400 mm ), otherwise the program identifies two floor space Its the same height. In the program, the correct way to set the wrong layer is to have the wrong layer The floor is divided into two layers, and the floor is set up in the entire room. Its important to note that PM - The second input beam floor board has the wrong floor and the wrong beam The button of the layer, these two buttons only affect the effect of the drawing, not to calculate any shadow Ring. (when the floor of a high-rise building is more complicated, or for the wrong layer structure, the structure goes There will be a local vibration, which should be chosen at this point Mandatory rigid floor assumptions To calculate the junction The periodic ratio of the construct. To filter the period of local vibration. ) For masonry structures, avoid the fault layer as much as possible, and if you cant avoid the wrong layer, you should Sew at the wrong layer, then calculate separately. 2. The structure with temperature joint, settlement seam and aseismic joint The framework can be calculated as a whole. For masonry structure, the structure should be divided into several parts according to the position of the seam PKPM It is impossible to calculate the total stiffness of the wrong layer during the aseismic test, so The calculation results have no reference value. The structure of each part is calculated independently It is meaningless to the earthquake. Second, In the use of SATWE Problems should be paid attention to when calculating 1. Corner columns should be defined in special c

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档