采用磨内喷水的几点体会(Some experience of using water jet in grinding).doc

采用磨内喷水的几点体会(Some experience of using water jet in grinding).doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
采用磨内喷水的几点体会(Some experience of using water jet in grinding) Author: unit: [2008-9-19] Keyword: cement grinding - water jet Abstract: 4 3.8m 12m * cement grinding machines in a plant are made of water jet in the mill. Spraying a small amount of mist water into the grinding bunker of the cement mill can reduce the temperature in the mill and restrict the electrostatic adsorption of the fine powder, thus avoiding the phenomenon of wrapped ball and improving the grinding efficiency. Especially in fine grinding pure clinker cement, the effect of water spraying in grinding is more remarkable. When the clinker reaches a temperature of more than 80 DEG C, spraying 1% to 1.5% of the atomized water into the mill can reduce the temperature of the grinding cement by 15% to 20%, and the output of the pure clinker can be increased by 5% to 10%. The temperature in the mill decreases and the dehydration of the gypsum is avoided, thus ensuring the quality of the cement. Water spraying is usually limited to grinding bins, but if the clinker reaches a temperature of more than 80 DEG C, water can be injected into a warehouse, so that the temperature of a silo is not more than 110 degrees centigrade. I will introduce the use of our factory. Working principle: at the discharge end, the injection of water is controlled by the cement temperature (MOIT3); the feed end is controlled by the temperature of the water shield (MOIT1). The following are stated below: The cement temperature (MOIT3) is measured by the thermocouple at the outlet of the mill. After the signal is amplified, and the regulator (PIU) compares the adjustable reference signal, if there is a difference between the two signals is open or close in water valve (K04), until the cement temperature has required evaluation so far. Water cover plate temperature (MOIT1) by the mill covered platinum resistance water plate pipe in the measurement of the regulator (PII), the signal is compared with an adjustable reference signal, the tw

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档