网站大量收购独家精品文档,联系QQ:2885784924

钢筋保护层厚度超标的危害和预防(Harm and prevention of excessive thickness of reinforcing layer).doc

钢筋保护层厚度超标的危害和预防(Harm and prevention of excessive thickness of reinforcing layer).doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
钢筋保护层厚度超标的危害和预防(Harm and prevention of excessive thickness of reinforcing layer) Harm and prevention of reinforced protective layer thickness exceed the standard. According to GB-50204-2002 concrete structure construction quality acceptance requirements, in the acceptance of concrete sub project shall be carried out before the structure test, one of which is affected by the thickness of reinforcement component protection test. This test is different from the installation of reinforced steel project in the allowable deviation of test group, to reflect the validation check an important indicator of the quality of the project. Structural concrete protective layer thickness inspection requirements In accordance with the relevant requirements, should pay attention to the following aspects. 1, reinforced protective layer thickness error of the test requirement is not greater than 1mm. This requires the use of reinforced protective layer measuring instrument and its accuracy must be not less than this value, and should be tested every engineering to choose the appropriate parts of the local grooving or drilling, to compare the necessary calibration. The 2 component, the protective layer thickness is the main test beams and plates, especially cantilever member. The control points are the main force for steel, bearing capacity and durability of the mobile position will significantly affect the component. 3, test of protective layer thickness of beam, plate steel, to select representative parts, i.e. beam and board member lower middle span is at the maximum bending moment and the upper root end negative moment at the maximum. 4, test of reinforced protective layer of beams and slabs should be inspection and evaluation, comprehensive evaluation can not be mixed together. The acceptance shall be qualified rate of test results should be greater than or equal to 90%. When the first test pass rate of less than 90%, but greater than or equal to 80%, can be drawn again and again the

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档