直线法在接地阻抗测试中的互感分析 analysis on mutual inductance with beeline method in the grounding impedance test.pdfVIP

直线法在接地阻抗测试中的互感分析 analysis on mutual inductance with beeline method in the grounding impedance test.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
直线法在接地阻抗测试中的互感分析 analysis on mutual inductance with beeline method in the grounding impedance test

《宁夏电力》2013 年第3 期 直线法在接地阻抗测试中的互感分析 李 勇 (宁夏电力公司电力科学研究院, 宁夏 银川 750011 ) 摘 要: 为了分析引线间的互感,根据镜像理论建立电流极引线在土壤中的镜像和测量系 统模型,计算测试引线间的互感抗;并将现场测得的接地阻抗数据分解为阻性成分和感性成 分。计算结果与接地阻抗测量结果的对比显示,引线间互感在接地阻抗测量值中所占比重不 容忽视。分析结果表明:确保接地阻抗测量结果的准确性,不仅需要对试验结果进行修正处 理,还要在测量时避免电流、电压极引线近距离平行布置。 关键词: 测量误差; 平行直线法; 引线间距; 互感 中图分类号:TM 133 文献标志码: A 文章编号:1672-3643(2013 )03-0025-05 有效访问地址: / 10.3969/j.issn. 1672-3643.2013.03.007 Analysis on mutual inductance with beeline method in the grounding impedance test LI Yong (Ningxia Electric Power Research Institute,Yinchuan Ningxia 750011, China) Abstract: In order to analyze mutual inductance between the down-leads, based on the mirror im⁃ age theory builds a mirror image and measurement system model of current pole down-leads in the soil, calculates the mutual inductance between the test down-leads, and separates grounding imped⁃ ance measured data of field test into resistance component and inductive component. The comparison of calculation result and measuring result displays that there is a large proportion of the mutual induc⁃ tance between the down-leads in grounding impedance measurement values. The analysis result shows that in order to acquire the veracity of measurement result of grounding impedance, ont only need make the modifying treatment for test result but also need avoid the voltage and current pole down-leads parallel arranging in the test. Key words: measurement errors, parallel lines method, lead spacing, mutual inductance DOI: 10.3969/j.issn. 1672-3643.2013.03.007 发、变电站接地网的接地阻抗合格与否是关 文献[1]中有明确的规定,但是部分地区和单位受 系到电力系统安全稳定运行、保障人身和设备安 传统习惯和客观条件的影响,测量接地阻抗时

您可能关注的文档

文档评论(0)

xyz118 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档