春兰故障代码(Chunlan fault code)

春兰故障代码(Chunlan fault code) E1 exhaust pipe temperature is too high E2 compressor overcurrent E3 power phase sequence error E4 system pressure is too high E5 system pressure is too low E6 anti freeze protection Fault code type: Chunlan KFR--120LW/BP Display code fault content E0 communications failed E1 open circuit for outdoor sensors. Short circuit E2 compressor overload E3 overcurrent E4 IPM protection E5 outdoor tube temperature is too high E6 exhaust temperature is too high E7 over voltage protection E8 indoor unit, sensor open circuit, short circuit New Chunlan 2005 fault code V series air conditioning E1 exhaust pipe temperature is too high E2 compressor overcurrent E3 power phase sequence error E4 system pressure is too high E5 system pressure is too low E6 anti freeze protection Chunlan KFR-40, 50, 70, 100, and 140LW/BdS fault codes Display content failure reason E1 indoor and outdoor communication failure (voltage between GND and CMM is swinging around 6-7V) E2 compressor overcurrent E3 abnormal supply voltage E4 refrigeration system pressure is too high to protect, RT5 sensor abnormal E5 outdoor ring temperature is too low protection E6 supercooling protection (cooling state) RT2 exception E7, RTI, RT2, RT3 temperature sensors open E8, RTI, RT2, RT3, temperature sensor short Chunlan FR-180 and 260/S wind pipe machine fault code Display code fault reason Chunlan air conditioning fault code Author: Zhang Ren release time: 2009-03-25 source: Taian Suzhou refrigeration equipment Co., Ltd. Click: 928 Chunlan 50 and 70 inverter air conditioning fault code E0 communication failure E1 outdoor sensor short-circuit E2 compressor protector protection E3 overcurrent E4 power module protection E5 outdoor tube temperature is too high E6 compressor exhaust temperature is too high E7 voltage is too high E8 indoor sensor short-circuit E9 indoor pipe temperature is too high Chunlan KFR--70LW/Bd attention: do not know which manufacturers electric control board? E1: communica

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档