- 1、本文档共7页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
高级技师试题(Senior technician test)
高级技师试题(Senior technician test)
First, the right and wrong
1, when the movable knife switch and the high-voltage isolating switch static contact breaking, the arc is generated by compressed air to blow out the long arc. ()
The neutral point of the power supply system of the 2 hidden content to get 9, 35kV is the operation mode of arc suppression coil grounding, so when single-phase grounding, grounding the two phase voltage is still as phase voltage. ()
10, 10kV power supply system uses neutral ungrounded operation, the purpose is to continue operation when single-phase grounding occurs. ()
11, in order to avoid the protection of zero line (PE line) disconnection, in the protection of the zero line, no switches and fuses are allowed. ()
12, two vertical buried grounding electrode together with the total grounding resistance, the distance between the poles is smaller than the distance between the poles. ()
13, as long as the iron pipe buried in the ground, can be a natural grounding. ()
14. The measured grounding resistance should be carried out under the condition of soil drying season and power failure. When the soil moisture content is large, the measured grounding resistance value shall be multiplied by the seasonal coefficient less than 1.
15 、 AC voltage withstand test is the reference condition to determine whether the electrical equipment can be put into operation. ()
16. To measure the absorption ratio of insulation resistance, the insulation condition can be judged by the ratio of the insulation resistance of 15s (molecule) and 60s (denominator). ()
17 、 dual arm bridge used to measure the DC resistance of 1~10 6. ()
18. Measuring the insulation resistance of electrical equipment is the only effective method to check the insulation state of electrical equipment and determine whether it can be put in or continued operation. ()
19 basic safety appliances can be operated or operated on high voltage live equipment.
20, 35kV (electroscopes) can be voltage indicat
您可能关注的文档
- 第二届bim大赛任务书(Task list for the second BIM competition).doc
- 第二期seo相关知识(Second SEO related knowledge).doc
- 第二次翻译练习心得(Second translation exercises).doc
- 第二章 中世纪文学概述_001(The second chapter is an overview of medieval literature _001).doc
- 第三次修复(Third repair).doc
- 第二章 神经肌肉的一般生理特性(The second chapter is the general physiological characteristics of neuromuscular).doc
- 第二章 掺杂技术(The second chapter doping technology).doc
- 第二章_汽车电子技术(The second chapter _ automobile electronic technology).doc
- 第二章室内设计与人体工程学(The second chapter is interior design and ergonomics).doc
- 第二章认识世界和改造世界(The second chapter is to understand the world and transform the world).doc
文档评论(0)