高级技师试题(Senior technician test)

高级技师试题(Senior technician test) First, the right and wrong 1, when the movable knife switch and the high-voltage isolating switch static contact breaking, the arc is generated by compressed air to blow out the long arc. () The neutral point of the power supply system of the 2 hidden content to get 9, 35kV is the operation mode of arc suppression coil grounding, so when single-phase grounding, grounding the two phase voltage is still as phase voltage. () 10, 10kV power supply system uses neutral ungrounded operation, the purpose is to continue operation when single-phase grounding occurs. () 11, in order to avoid the protection of zero line (PE line) disconnection, in the protection of the zero line, no switches and fuses are allowed. () 12, two vertical buried grounding electrode together with the total grounding resistance, the distance between the poles is smaller than the distance between the poles. () 13, as long as the iron pipe buried in the ground, can be a natural grounding. () 14. The measured grounding resistance should be carried out under the condition of soil drying season and power failure. When the soil moisture content is large, the measured grounding resistance value shall be multiplied by the seasonal coefficient less than 1. 15 、 AC voltage withstand test is the reference condition to determine whether the electrical equipment can be put into operation. () 16. To measure the absorption ratio of insulation resistance, the insulation condition can be judged by the ratio of the insulation resistance of 15s (molecule) and 60s (denominator). () 17 、 dual arm bridge used to measure the DC resistance of 1~10 6. () 18. Measuring the insulation resistance of electrical equipment is the only effective method to check the insulation state of electrical equipment and determine whether it can be put in or continued operation. () 19 basic safety appliances can be operated or operated on high voltage live equipment. 20, 35kV (electroscopes) can be voltage indicat

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档