必须检查的计算结果输出信息(The calculated results must be checked for output information).docVIP

必须检查的计算结果输出信息(The calculated results must be checked for output information).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
必须检查的计算结果输出信息(The calculated results must be checked for output information)

必须检查的计算结果输出信息(The calculated results must be checked for output information) The calculated results must be checked for output information 1, Axial compression ratio: mainly for the control of structural ductility, the specification of the wall, limb and column have corresponding limit requirements, see the anti gauge 6.3.7 and 6.4.6. 2, Shear weight ratio: mainly for the control of the floor minimum seismic shear, to ensure structural safety, see high gauge table 3.3.13; seismic specifications table 5.2.5 the same. If the minimum seismic shear coefficient of the calculated storey fails to meet the requirements of the code, the choice of whether or not to adjust the seismic shear force will be given. According to the explanation of the specification group, if the structure is not satisfied, the structural scheme should be adjusted until the standard value is reached, but the seismic force can not be simply increased. 3, stiffness ratio: mainly for the vertical structure control rules, so as to avoid vertical stiffness mutation, forming a weak layer. The new seismic code appendix E2.1 stipulates that the lateral stiffness ratio of the upper and lower layers of the transfer storey structure shall not be greater than 2. The 4.4.3 of the new regulation stipulates that the lateral rigidity of the floor structure of seismic design shall not be less than 70% of the lateral stiffness of the upper storey or 80% of the average lateral rigidity of the three storey The provisions of article 5.3.7, high compliance, calculation of high-rise buildings, the basement roof as the upper structure of fixed end, 2 times of the lateral stiffness of the basement structure should not be less than the lateral stiffness of the structure of the adjacent upper floors. All of these stiffness ratios are related to the calculation of floor stiffness. Currently, there are three options available: (1) the method proposed by the high standard appendix E.0.1 - shear stiffness Ki=GiAi/Hi (2) the metho

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档