about on the design of reinforced concrete rectangular pool(在钢筋混凝土矩形池的设计)

About On the design of reinforced concrete rectangular pool Abstract: Reinforced concrete rectangular pool structure as a special type of common, widely used in industrial and civil buildings range water supply, sewage, fire works, so the water in the process to meet the requirements of the premise, both to ensure the future of the normal production use, and reduce the project cost, is the main task facing the designers below to design some of the problems often encountered, a few comments. Keywords: rectangular pool, design, points A load value problem 1.1 pool of water pressure. Pool water pressure tank type structures as the main load. In the design process, should be at least somewhat safe height to calculate the water pressure. This is because: one using the process probably due to neglect of duty or the presence of liquid level meter and other components caused by failure of full pool, on the other transformation process on the future rather than the original design may be the water level. pool size values ??of the load pressure retaining wall for the bottom of shallow pools moment a greater impact. 1.2 external water buoyancy pool when there is groundwater, in addition to considering the lateral wall of groundwater pressure, should also consider the soil below the water table so that the soil due to water buoyancy reduces the effective and severe impact on the earth pressure the same time, groundwater of the cell body of the uplift can not be overlooked. As the water table caused by the structure that did not have a good selection of error and inadequate anti-floating construction accidents have also occurred. Geological Survey report provided by the general water table water table only reflects the situation during the investigation, if carried out detailed exploration at the local dry season, provided the water table elevation will not be designed to access or lead to errors in calculating the structure according to the actual situati

您可能关注的文档

文档评论(0)

jiupshaieuk12 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档