电站电气倒闸操作误操作原因分析(Cause analysis of misoperation of electrical switching operation in power plant)

电站电气倒闸操作误操作原因分析(Cause analysis of misoperation of electrical switching operation in power plant) Switching operation is the power plant (substation) priority among priorities of work safety, operation personnel such as misuse occurred in the process of switching operation, light to cause the shutdown, line trip, weight is likely to cause a blackout, endangering the equipment and personal safety and power grid, and the social impact, so the switching operation the work should pay great attention to and strengthen prevention. 1. Analysis of misoperation of electrical switching operation in power plant 1), switching operation without reasonable arrangement of operating personnel, such as poor health or bad mood of the operating personnel to operate, uneven quality of the business operation personnel, safety consciousness, lack of awareness, that fill in or perform an operation ticket, take safety measures is only one task, is to cope with examination, ignore this to ensure their own interests. The electric operators carry out shift work, and the individual attendants are easily fatigued when they are working, especially after the night shift. At this point, if the operation of the switch is not upgraded, the memory error may occur and lead to an accident. 2), switching operation when the tool is not fully prepared or unqualified instruments, such as the use of ultra cycle electroscope and levers, insulating gloves leak not timely replacement, may affect the safe operation. Therefore, periodic tests must be carried out to ensure that the operating tools are in good condition. The actual work in preparation for the joint shall be in accordance with the provisions of the 2, but the actual process due to the lack of supervision and inspection procedures, operation missing thatlittle or prolong the operation time of drag in all sorts of irrelevant matters. There are even safety appliances and safety measures without lighting or other causes of electric shock or wrong separa

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档