新建绣花维修知识(New embroidery maintenance knowledge) *1, spindle motor abnormal Check whether the switch on the motherboard is in line with the motor (that is: slip, servo, frequency conversion) Check whether the operating box parameters are consistent with the spindle motor parameters; Servo drive parameter control mode numerator denominator is correct; Check the needle bar box for mechanical card dead center. Check whether the external input voltage is normal, whether or not the phase is missing, whether the terminal is loose; whether the W, U and V are connected; Check the encoder: measure the A phase, the B phase, and the Z to measure the signal relative to the normal; C4 board fault Motherboard fault *2 and no lock pulse Measurement of C8 board in a 24V power supply, no check F1 (20V/10A or 15A insurance), such as the replacement to replace the damaged; check whether there is damage to C8 in short circuit; without damage inspection and rectification bridge AC20V; Check whether the flat plug connections from the C4 to the C1 board are loose; C4 board fault; Motherboard fault. *3, take place Check the drive 110V - 220V voltage is normal; Check if the stepping motor line is loose; See X and Y to promote the embroidery have mechanical card dead; Check whether there is a frame frame wheel wear, affiliated is loose; Check the stepping motor to lock the female top wire for loosening. *4, color change timeout Check whether the power line 220V is reversed to the positive and negative signal line; The C4B board malfunction results in excessive color change, not in place, or in one direction until the card dies; Open circuit or short circuit to ground; The needle bar case has mechanical card dead center; The color change cam grooves are not installed in the groove, and the assembly is not proper. *5 and scissors do not return position Enter the system test scissors can operate knife; Check the scissors have no delay, the motor torque is normal; Check if there is any signal inpu

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档