变电题库(Transformer bank)

变电题库(Transformer bank) Fill in the blanks 1, substation equipment patrol inspection, generally divided into (normal inspection (including handover classes, visits)) (comprehensive inspection) (special inspection) 2, standby or stand-by equipment shall be as regular as the running equipment (Patrol) and (maintenance). 3, set control stations on duty duty personnel should be in time to check the substation under the upload information, every two hours to all the substation (picture), (report), (upload information) comprehensive inspection. 4, storage battery should check (voltage), (temperature) meet the requirements, whether the joint connection is fastened, whether there is fever, oxidation, the battery container has no (broken), (leakage). 5, substation comprehensive automatic machine inspection items: should visit the main wiring diagram and (actual equipment) position consistent, remote measurement is correct. We should visit the alarm window, event sequence record, (protection event record), remote change record, and (over limit alarm signal) to check whether there is any abnormal signal. 6, emergency cases, oil immersed, self cooled and air-cooled transformers allow short-term overload operation, environmental temperature at 20 degrees and below, allowing overload (30%), the ambient temperature of 30 degrees, allowing overload (15%). But the overload running time is not more than (24) hours. 7, voltage ratio and different impedance voltage of transformer in any one will not overload situation, can run in parallel, but the voltage difference should not be more than (1%), impedance voltage difference should not exceed (10%), capacity ratio should not exceed (1/3), transformer connection to different groups of non parallel operation, different transformer impedance voltage should be increased two times the voltage transformer impedance voltage of transformer capacity, so that can make full use of. 8. The voltage regulating operation of on load voltage regulating d

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档