生物柴油馏程测量不确定度的评估
JOURNAL OF INSPECTION AND QUARANTINE 检验检疫学刊 Vol.24 No. 3 2014 年第 3 期
生物柴油馏程测量不确定度的评估
徐晓霞 谭智毅 毛容妹 梁炜峰 唐志锟 张海峰
(广东出入境检验检疫局 广东广州 510623 )
摘要摘要 介绍了生物柴油馏程测定过程中检测结果不确定度的评估方法。通过找出影响回收温度结果的各
种因素,并对不确定度分量进行了合理评估,推算生物柴油标准要求各回收温度测量不确定度以及回收体积
等不确定度,得出了生物柴油检测结果的合成不确定度。通过评估,可以提高检测结果的可靠性,增强检测
结果之间的可比性。
关键词关键词 生物柴油; 馏程; 不确定度; 评定
中图分类号中图分类号 TQ517
Evaluation of Uncertainty in Measuring the Distillation Temperature of Biodiesel Oil
Xu Xiaoxia, Tan Zhiyi, Mao Rongmei, Liang Weifeng, Tang Zhikun, Zhang Haifeng
(Guangdong Exit-Entry Inspection and Quarantine Bureau, Guangzhou, Guangdong, 510623)
Abstract: This paper introduces evaluation method of uncertainty for distillation temperature of biodiesel. The factors
of recovery temperature were found, and the uncertainty components were evaluated reasonably. Then we carried out
,
the uncertainty of recovery temperature and recovery volume for biodiesel, and calculated the combined uncertainty of
those distillation temperatures, we were able to improve the reliability of the test results by the assessment.
Key Words: Biodiesel Oil; Distillation; Uncertainty; Assessment
1 前言 能通过减压馏程测量降低其蒸气温度来实现。
生物柴油是生物资源原料在催化剂参与下, 按照 GB/T 9168-1997[6]或ASTM D1160-13 [7]
与甲醇或乙醇等醇类物质经酯化反应生成脂肪酸 标准要求对生物柴油进行减压蒸馏,在测量过程
甲(乙)酯,最终变成可供柴油机使用的清洁、 中 , 存 在 着 大 量 影 响 测 量 结 果 的 因 素 , 主 要 有
可 再 生 液 体 燃 料 , 它 是 优 质 的 石 化 柴 油 替 代 燃 重复性测量、回收体积、试样质量、测试压力、
料,素有“绿色柴油”之称[1] 。与石化柴油相比, 温 度 传 感 器 、 数 值 修 约 等 引 入 的 不 确 定 度 , 这
生物柴油在环保、低温发动机启动性、润滑性、 将导致结果产生一定的分散性。本研究根据 JJF
原创力文档