输电线路发生单相接地短路后采样周期对测距精度的影响输电线路发生单相接地短路后采样周期对测距精度的影响
Smart Grid 智能电网, 2016, 6(2), 47-55
Published Online April 2016 in Hans. /journal/sg
/10.12677/sg.2016.62006
Influence of Sampling Period on the
Accuracy of Single Phase to Ground
Fault in Transmission Line
Xiangfei Meng, Yijun Sun, Hongmin Hao, Jian Wang
College of Electrical and Electronic Engineering, Shandong University of Technology, Zibo Shandong
th th st
Received: Mar. 14 , 2016; accepted: Mar. 29 , 2016; published: Apr. 1 , 2016
Copyright © 2016 by authors and Hans Publishers Inc.
This work is licensed under the Creative Commons Attribution International License (CC BY).
/licenses/by/4.0/
Abstract
We analyze the basic principle of power frequency fault location of single-phase to ground fault in
three-phase system of transmission line and use PSCAD/EMTDC simulation software to build the
transmission line distributed parameter model. According to the transmission line single-phase
grounding short circuit fault simulation, we use the Fourier algorithm to extract cycles of failure
and calculate the voltage and current of power frequency to fault location, which is based on pow-
er frequency component of single end fault distance measurement principle. And current power
frequency is analyzed by using the Fourier algorithm. Based on the real time fault data collected
by the recorder in the single phase to ground fault in the small sand 110 KV large Xiapu Fujian
wind line, the influence of the sampling period on the ranging results is verified. It can be used for
referencing in the selection of sampling period when using power frequency to carry out fault lo-
cation.
Keywords
Transmission Line, Simulation Modeling, Fault Location, Case Study
输电线
您可能关注的文档
- 超级无敌——店长成长篇超级无敌——店长成长篇.ppt
- 超级珍贵的绩效管理实用工具分析免费分享啦超级珍贵的绩效管理实用工具分析免费分享啦.pdf
- 超级门市接单的十大步骤超级门市接单的十大步骤.doc
- 超市美工注意事项超市美工注意事项.ppt
- 超经典综合单价分析习题超经典综合单价分析习题.ppt
- 超薄型防火应用检验技术要求20128110384246超薄型防火应用检验技术要求20128110384246.pdf
- 超赞人教语文三年级1-8单元复习题卡超赞人教语文三年级1-8单元复习题卡.doc
- 超越现代与后现代史学_评韩震_董立河的_历史学研究的语言学转向_超越现代与后现代史学_评韩震_董立河的_历史学研究的语言学转向_.pdf
- 超越自我材料作文超越自我材料作文.doc
- 超越认知:情感领导力与情绪劳动超越认知:情感领导力与情绪劳动.pdf
文档评论(0)