- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
演示文稿演讲PPT学习教学课件医学文件教学培训课件
Haemodynamic Monitoring Theory and Practice Haemodynamic Monitoring Physiological Background Monitoring Optimising the Cardiac Output Measuring Preload Introduction to PiCCO Technology Practical Approach Fields of Application Limitations Knowledge of the limitations is essential for correct interpretation of the data! Limitations of the PiCCO parameters - thermodilution Limitations GEDV data will give false-high with large aortic aneurysm is not usable with intracardiac left-right shunt can be overestimated in severe valvular insufficiency EVLW data will be falsely high with gross pulmonary perfusion failure (macro-embolism) is not usable with intracardiac left-right shunt can only be used with fully controlled mechanical ventilation (minimal tidal volume 6-8ml/kg) and absence of cardiac arrhythmias (otherwise may give false high reading) Knowledge of the limitations is essential for correct interpretation of the data! Limitations of PiCCO parameters – pulse contour analysis Limitations SVV / PPV not valid when an IABP is in use (thermodilution is unaffected) All parameters of pulse contour analysis PiCCO Technology in special situations Special clinical situations normally no interference with the PiCCO parameters Renal replacement therapy Prone positioning all parameters are measured correctly Peripheral venous injection not recommended, measurements possibly incorrect Limitations of application of PiCCO Technology Limitations Because of the use of normal saline as indicator, PiCCO measurements are possible at virtually any desired frequency, even in children (over 5kg) and pregnant women. PiCCO Technology has no specific limitations of application Contraindications to PiCCO Technology Limitations The usual precautions are required when puncturing larger blood vessels: ? coagulation disorders ? vascular prosthesis (use other puncture site, e.g. axillary) Because of the low invasiveness there are no absolute contraindications The complication
您可能关注的文档
- (精选)【医学课件课件】结直肠癌变各阶段的全基因组外显子测序结合数字化表达谱研究教学课件.ppt
- (精选)MicroRNAs regulate the expression of the alternative splicing factor nPTB during the muscle development教学课件.ppt
- (精选)【医学课件课件】结直肠肿瘤病理诊断和治疗中的几个新概念教学课件.ppt
- (精选)microRNAs 的重要性教学课件.ppt
- (精选)【医学课件课件】結膜弛緩症教学课件.ppt
- (精选)microRNAs 的作用 (role of microRNA in chemoresistamce)教学课件.ppt
- (精选)【医学课件课件】節制飲酒計畫教学课件.ppt
- (精选)microRNA的作用与调控机制教学课件.ppt
- (精选)【医学课件课件】截断逆挽法治疗慢重肝教学课件.ppt
- (精选)microRNA和癌症(Regulation of microRNA processing and its implications for development and cancer)教学课件.ppt
- 实验活动简单配合物的形成课件-高二下学期化学人教版选择性必修2.pptx
- Unit3SectionB(1a-1e)课件人教版八年级英语上册.pptx
- Module6Unit2课件外研版英语九年级上册.pptx
- 第2课これは本です课件-高中日语新版标准日本语初级上册.pptx
- 山西省临汾部分学校2024-2025学年高一下学期期末联考试题政治.docx
- 第19课北洋军阀统治时期的政治经济与文化(互动型课件)-中外历史纲要上册新课件(统编版).pptx
- 第高一下学期统编版必修中外历史纲要下(1).pptx
- 科技擂台第10节捏面人大赛(课件)-科学二年级上册冀人版.pptx
- 第19课北洋军阀统治时期的政治经济与文化(情境化教学课件)历史统编版中外历史纲要上.pptx
- Unit1Lookitup!(Grammar)课件沪教版八年级英语上册(1).pptx
文档评论(0)